Make Model Symptom Problem Solution By
PHILIPS 20PT4331
No sound, increased after a certain time C 2444 (470 uf) changed Is close to the fly cabeção natal
PHILIPS FW-C380
Crackling sound, as if connecting and disconnecting the speaker (like bad contact) I tested everything that is part of the audio and nothing, I even changed the ci 7501-tda7468, and the 4558 without success Capacitors c2601, c2602 1nf smds at output 12,17 of the tda 7468 and that's it az09(elizeu) This email address is being protected from spambots. You need JavaScript enabled to view it.
PHILIPS DVP3254K
No sound Ce26 =220/16v with leakage Bruske
PHILIPS 14PT110B
Image pushed to the left side and without OSD Tda 8660e from line 5 y Replace for one of the same good luck EVALDO GOMES URUÇUI-PI
PHILIPS 14PT110
As soon as it turns on, there is little shine, slightly off focus, very strong color, appearing to be a tube. Dark screen gradually brightens The only defect was the tube socket. This email address is being protected from spambots. You need JavaScript enabled to view it.
PHILIPS 20PT3331/78R
Closing vertical top C2465(10u/160volt's) jarbas santos
PHILIPS 21 PT9467
Stop Resistor 39k aauterated breastplate ci da power supply
PHILIPS 29PT4635
L01.1L AC2K3
Does not turn on, the LED sometimes lights up, the voltage at the base of 7461 and 7463 was 0.11v and at the emitter it was 0.37v, the other voltages were all normal. Solution: transistor 7406 bu4508dx -> horizontal output *note: the low voltages made me change the transistors 7461, 7463 and the capacitor 2455 but after changing them the voltages remained low, so I concluded that this was due to a short in the secondary of the transformer 5461 this is because of the transistor 7460 -> horizontal output which was burnt and causing a small leak between collector and base and as its base is connected to the secondary of the 5461 this caused a short in it which was reflected in the primary and killed the voltages of 7461 and 7463. This email address is being protected from spambots. You need JavaScript enabled to view it.
PHILIPS AZ1134
Cd after a while of use gives an error 6 volt power supply from CD dropping Replace q3, q7 and q11, place bc337/25 close to the board ars
PHILIPS 20PT 3331
Black band 05 cm vertically and lines below it doubles the vertical Replace capacitor 2465 10nf/160v pedro ironei jr assitel eletronica
PHILIPS 29PT
TV threatening to close the horizontal Electrolytic capacitor c 2458 2.2mf 100v and replace the wide capacitor john games
PHILIPS/MAGNAVOX 20MT2136
Does not turn on (electrical discharge) No power reaches the photocoupler. Replace ic 7520 Eronaldo
PHILIPS 21PT5433/78R
L03.1 L
Does not work (it remains switched off) Resistor 3445 and 3446 (both 1r) open Checked the voltage at pin 2 (ic7520) of 13.8v, and main supply of 97v, both ok! then I found that I didn't have the voltages of -12v (diode 6446) and 160v (diode 6447) due to the open resistors. Anderson Viana - Manaus
DVD PHILIPS 3254K
No audio Capacitor ce 26 220 x25v Replaced, it was ok aliomarp
PHILIPS 14GX1619
Inoperative power supply does not arm Crimping the horizontal output and with very high tension on the altered fly back pacifier Replace o fly back eletroclaudio aguas belas pe
PHILIPS 14GX1619
White screen with colored retrace lines on the front side and no video Defective vertical outlet Replace the same eletroclaudio aguas belas pe
PHILIPS 21PT5435
It has sound, no image and no characters. I measured the screen voltage it was zero. I came to the conclusion that the tube was shorted, I removed the socket and the deflector and tapped around the kinescope tube and the short disappeared. I put the deflector and socket in place. the screen tension arrived and the image appeared normally. Kinescope with shorted grids, consuming screen voltage. VALDO RECIFE
PHILIPS 20PT4331/78R
Turns off on tuned channels, in AV it works normally R3449 open Replace of the same paulo
PHILIPS 20PT3331
L0
Customer said that he had gotten water through the antenna; well the power supply was a little low, I cleaned it in the photo attached to the power supply, it started to turn on but it turned off in 3 seconds then it was really bad, the defect was just the scrin joint and it was very low and it turned off then It just increased, it was ok 88178817 francisco mutirao Increase the scrin potentiometer as much as possible, everything is ok, good luck Let's help everyone because it's great when you find a tip from a friend who gives a big hug to professional friends marcos melo cascavel ceara
PHILIPS 20GX 1659
Disarming After checking everything - stand bi power supply I noticed that when it was turned off the vertical stretched, I replaced it but the defect continued Solution I replaced the two electrolytic caps, it worked great - no more disarming hug jose santos vicente