PHILIPS K40
Blank screen - sound ok (field collapse) 3186 1r5 o/c, 2171/2175 1µ 63v caps (rh edge of sigs pcb)
PHILIPS K40
Blank raster pin 16 tda2541 low ( not 5.2v ) or pi If pin 16 low c2115 if 1 low capacitor on pin 2 22nf
PHILIPS K40
Blank raster - no sound or vision. C2115 ( 33nf ) leaky.
PHILIPS K35
Tuning - drifting with horizontal white bars. D0 (B1)
PHILIPS K35
Slow warm up - dark picture. C583 ( 4.7u f , 250v ) decouples 115v supply to rgb o/p.
PHILIPS K35
Remote - intermittent. D32 leaky.
PHILIPS K35
No remote control. Check for dirty contact on ic1 holder pin 13.
PHILIPS K35
No field R590 o.c. , c521 s.c. 1.2Ω and 1500mfd 25v
PHILIPS K35
Loses memory at switch off Check power sub panel bottom of cabinet.
PHILIPS K35
Ht comes up then shuts down - e1 in display Drys on con ltb.
PHILIPS K35
Go into standby if tapped Check thermistor
PHILIPS K35
Ew bowing 5r on coll of ts490 open
PHILIPS K35
East west. T1490 dry , y1485 leaky.
PHILIPS K35
Dead - up in smoke 8.2n 2kv cap in line stage arcing conn
PHILIPS K35
Dark pic C583 4.7uf 250v
PHILIPS K35
Changing tuner - use u342lo with mod. Mod type see tv mag.
PHILIPS K35
Blank raster with bright defocused line. R455 ( 560r ) dry jointed or o/c.
PHILIPS K30
Tripping. Supply reservoir r pacitor c1460b , 285v.
PHILIPS K30
Tripping. C1567 ( 8.2nf , 1.5kv ) o/c , may have blown loptx.
PHILIPS K30
Tripping. C1560a ( 200uf ) o/c , c14606.