Make Model Symptom Problem Solution By
PHILIPS K30
Tripping - intermittent trip ng. Loose aquadag crt earthing braid.
PHILIPS K30
Sync - loss of line hold. C7341 ( 0.0012u f ) s/c.
PHILIPS K30
Switching off then back on. Dry on bead at the end of eht lead in loptx socket.
PHILIPS K30
Startup - slow warm up. C583 ( 4.7u f , 250v )
PHILIPS K30
Startup - intermittent no startup. C1460a/b going o/c.
PHILIPS K30
Picture going red , green or blue. 1st anode controls going o/c.
PHILIPS K30
Noiseless raster. R1412 ( 12r ) intermittent o/c.
PHILIPS K30
No startup. C1460a/b going o/c.
PHILIPS K30
No red - intermittent. C3046 ( non-text ) , c2171 ( text )
PHILIPS K30
No picture - after around twenty minutes. Dry on pin 1 of u7 sound panel/mother pcb connector.
PHILIPS K30
No controls manual or remote operation Ic 005 15v reg.
PHILIPS K30
No colour - intermittent. Drys on tag 4 of sync module.
PHILIPS K30
Low field + severe flyback lines R585 high ( lowers 13v supply rail )
PHILIPS K30
Lines with no luminance or chrominance. R8380 ( 47r ) o/c.
PHILIPS K30
Goes green when warm Green 1st anode pot int
PHILIPS K30
Frame collapse. R1590 o/c.
PHILIPS K30
Frame collapse. C1521 ( 1 , 500uf ) s/c , r1590 ( 1.2Ω ) o/c.
PHILIPS K30
Frame - collapse partial. C1521.
PHILIPS K30
Frame - black band at bottom of picture. C1588 ( 690uf ) o/c.
PHILIPS K30
Field collapse No 32v supply, r1590 1r2 surge lim o/c, c1521 1500µ s/c