Search: philips
Results: 14210
Make Model Symptom Problem Solution By
PHILIPS FL2.16
Totally inoperative. power supply on hardware protection. Check the east/west protection, t7541 and t7540.
PHILIPS FL2.16
Totally inoperative. only red led on. Hardware protection. check t7441(bc847c) and t7440 (bc848c) on lsp. east/west protection.
PHILIPS FL2.16
Totally inoperative. only red led on. Check t7504 on lsp (on4673b; 4822 130 62934).
PHILIPS FL2.16
Totally inoperative. no eht voltage. Check d6536 (byw29f; 4822 130 80982).
PHILIPS FL2.16
Totally inoperative. hardware protection; error 99. Check ic7001 (tda1521q; 4822 209 63913).
PHILIPS FL2.16
Totally inoperative. hardware protection vertical deflection. Check ic7450 (tda3654q/n3; 4822 209 73308).
PHILIPS FL2.16
Totally inoperative. hardware protection is active (error 99). Check ic7001 (tda1521q; 4822 209 73311).
PHILIPS FL2.16
Totally inoperative. error99. Check lot 5555 (4822 140 10443).
PHILIPS FL2.16
Totally inoperative. eht voltage o.k. Check +13v. if too low, check ic7551 (lm358n; 4822 209 70672).
PHILIPS FL2.16
Totally inoperative. Micro sops does not start? check r3249 (220kΩ; 4822 116 52258).
PHILIPS FL2.16
Totally inoperative only stand-by led burns. Check t7506 (on4673 c; 4822 209 63912)
PHILIPS FL2.16
Total inoperative, leds blinking, error 99 Check and replace if necessary c2504 and/or 2505 (2kv hrr) on the large signal panel. replace by a 3kv15 hr-r capacitor if possible: 820pf 4822 126 13152 1nf 4822 126 13153 1,2nf 4822 126 13154 1,5nf 4822 126 13155 1,8nf 4822 126 13156 2,
PHILIPS FL2.16
Ticking noise and line in picture Transistor 7381 (bc848c; 5322 130 42136) defective when hot.
PHILIPS FL2.16
Synchronization, picture disappears D6703 and t7704 defective on picture tube panel.
PHILIPS FL2.16
Supply switch-off sometimes Check the +5 stand-by. this voltage has to be 5.5v and may not vary. when the voltage drops below 5.2v the set switches-off. cure: check d6266 for leackage (bzx79/f6v8; 4822 130 34278) or check t7268 for leackage (bd943f; 4822 130 62742). the 5.5v is meas
PHILIPS FL2.16
Supply +5v too low, black horizontal bar in picture. bad sync. Check/replace ic7551 (lm358n; 4822 209 70672)
PHILIPS FL2.16
Starts-up in service default. all control leds on. no standby. Check micro proccessor pwb (pos.7115; 4822 212 30803 + software 4822 900 10423).
PHILIPS FL2.16
Spook in picture Use special antenna cables. codenumbers: 4822 321 61224 pal 1 meter 4822 321 61225 pal 2 meter 4822 321 61226 secam 1 meter 4822 321 61227 secam 2 meter
PHILIPS FL2.16
Spoke on 134,25 and 287,25 mhz in proscan sets. Spoke on above mentioned frequency can be solved by adding two capacitors of 33pf (5322 122 32072) on the lfr box. - between pin 10 of h22 and earth (pin 5 of h22) (cvbs). - between pin 7 of h21 and earth (pin 4 of h21) (txt int).
PHILIPS FL2.16
Spare part information Spare part information ---------------------- new mainsswitch bracket fl2 sets. in week 9424 the bracket for the mainsswitch of the fl2 sets is changed from 4822 404 31286 into 4822 404 31415. it is not possible to use the new brackets (4822 404 31415) in