PHILIPS FL2.14
Spoke on 134,25 and 287,25 mhz in proscan sets. Spoke on above mentioned frequency can be solved by adding two capacitors of 33pf (5322 122 32072) on the lfr box. - between pin 10 of h22 and earth (pin 5 of h22) (cvbs). - between pin 7 of h21 and earth (pin 4 of h21) (txt int).
PHILIPS FL2.14
Spare part information Spare part information ---------------------- new mainsswitch bracket fl2 sets. in week 9424 the bracket for the mainsswitch of the fl2 sets is changed from 4822 404 31286 into 4822 404 31415. it is not possible to use the new brackets (4822 404 31415) in
PHILIPS FL2.14
Sound shuts off and osd in picture. Voltage on pin 4 tda8417 was 3.5v tt instead of >4.5v tt. replace x-tal 10 mhz (4822 242 80276).
PHILIPS FL2.14
Sometimes vibration in vertical direction. Replace c2410 (150nf 5%; 4822 121 41854) on lsp.
PHILIPS FL2.14
Sometimes in protection, or hor. width varies Check or resolder on lsp the pins of e/w bridge coil 5521.
PHILIPS FL2.14
Shuts off and on again on pr.nr. 1 after 3 hours. D6272 (bzx55b5v6) interruption when it becomes hot.
PHILIPS FL2.14
Set totally inoperative, no leds on. supply hums. R3252 220 kΩ (start-up micro-sops) defective (4822 116 52258).
PHILIPS FL2.14
Set sometimes goes in stand-by and immediately switches on again. Replace position ic7120 on lfr box (pcf83c652p/ab/043) by p83c652ffp/50 v34d (4822 209 33289). remarks : introduced in production in week 9337.
PHILIPS FL2.14
Set inoperative only red or green led. supply was 141v but no eht. Line drive puls for t7506 (2sc4288a) too low. l5503 defective (line drive coil; 4822 157 63252)
PHILIPS FL2.14
Set can only be operated with remote control Check whether "child lock" is disabled. to check this, see "frequently asked questions", "how to disable child lock".
PHILIPS FL2.14
Poor colors, no light in picture Check ic7207 (sda9205; 4822 209 31056).
PHILIPS FL2.14
Pip picture not in order. Check r3345 (4822 111 41424) in pip unit, check ic7755 (4822 209 63423).
PHILIPS FL2.14
Pip picture is not synchronized. Frequency on pin 15 ic7755 sometimes too high. check c2238 (2n7; 4822 121 42937).
PHILIPS FL2.14
Pip picture is not synchronized. Check synchronisation ic 7755 (tda2579b-2y) on pip panel.
PHILIPS FL2.14
Picture twists from top Voltage of pin 8-ic7450 (tda3654q) on the lsp has raised to ca. 20 v. check diode 6451 (bzx79/c5v6; 4822 130 80954).
PHILIPS FL2.14
Picture twists from top Voltage of pin 8-ic7450 (tda3654q) on the lsp has raised to ca. 20 v. check diode 6451 (bzx79/c3v6; 5322 130 34834 or bzx79/c10; 4822 130 61219)
PHILIPS FL2.14
Picture ok after some time Ic7207 (sda9205-2; 4822 209 31056) defective when set is cold.
PHILIPS FL2.14
Picture often dark Check ic7201 in high end-box (saa9042p/a; 4822 209 31851)
PHILIPS FL2.14
Picture gives black horizontal stripes, also on rgb Ic72027 sda9205-2 lfr box defective (4822 209 31056).
PHILIPS FL2.14
Picture disappears shortly after 30" or control does not function. When hot, 13,5 mhz clock stops working; change the value of r3123 to 1k2.