Philips Repair Tips
Search: philips
Results: 14210
Results: 14210
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
PHILIPS |
22GR9972
|
"mono f2" flashes up at odd times | Resolder sm ceramic caps on nicam pcb | ||
PHILIPS |
21ST2731/05
|
Picture shifted/blank one side | Ic7470 faulty tda2579b | ||
PHILIPS |
21PV688/39
|
St/by only | Check field chip & loptx - if field chip old type (with "5y" or lower) marking its the old type - order kit pt no 4822 209 16781 which includes chip & other parts | ||
PHILIPS |
21PV688/05
|
Switches to st/by at sw on | Caused by f o/p chip tda8356 (no heatsinjk compound), also r3512 4r7, r3541 1r | ||
PHILIPS |
21PV688/05
|
No pic | No heater supply to crt - r3532 & r3537 4r7 o/c | ||
PHILIPS |
21PV688
|
Tripping, led flashing red/green | Loptx u/s (4822 140 10655) | ||
PHILIPS |
21PV688
|
St/by only | Fus res 3514 4r7 3w o/c when tda8356 ic 7510 fop chip fails | ||
PHILIPS |
21PV688
|
Service mode - entering | Press 'stop' on hset & 'play' on front together for about 5 secs | ||
PHILIPS |
21PV688
|
Remote not working | Put in service mode, select 'service control' & click 'ok'. check option codes tally (on label at back of unit). if ok 'clear' eeprom | ||
PHILIPS |
21PV688
|
No video remote operation (tv sect ok) | Leave batts out of handset to discharge (several hours) | ||
PHILIPS |
21PV688
|
Int. shutting down after frame ic has been replaced | If replaced with later version 6 , also fit frame mof kit 4822 209 16781 | ||
PHILIPS |
21PV688
|
Dead, psu not running | R3338 39r 0.25w o/c (discharge mains cap first!) | ||
PHILIPS |
21PV688
|
Dead - safety res r3514 & 3592 o/c & d6524 s/c | Now tripping - tda6107q on crt base & fop chip faulty | ||
PHILIPS |
21PV330/07 DELTA 2000
|
Dead - loptr s/c - blows again few hrs aft replacement | Line dr trfr replacement cured it | ||
PHILIPS |
21PV320/05
|
Hotel mode removal | Select ch38. hold down stop on r/c & stop on tv for 5 seconds until he- is displayed. | ||
PHILIPS |
21PV288/05
|
Dead - 4a fuse o/c, d6313/4 bridge rect s/c | R3344 2r 5w o/c due to c2328 470pf 2kv arcing behind chopper tr heatsink | ||
PHILIPS |
21PV288
|
St/by only | Ic7881 saa5254 txt proc chip faulty | ||
PHILIPS |
21PV287/39
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
21PV267/02
|
Option code: 56300 | From week 02/97 onwards the option code is printed on the typesticker. always use this code ! for early sets without this information on the typesticker, the option code is: 57260. | ||
PHILIPS |
21PV267/02
|
New vps ic sda5642-6 (pos. 7840) | Since production week 9741 a new vps ic pos. 7840 (sda5642-6) is introduced in production. this ic is not compatible with the previous one. when ordering, look at the printing on the ic ! old: sda 5642-5 - codenumber 4822 209 32728 new: sda 5642- |