Search: philips
Results: 14238
Make Model Symptom Problem Solution By
PHILIPS 29GX1898/78R
Turn off inter. or protect (rew 3 for vcr). Leaky 6446 diode.
PHILIPS 29GX1898/78R
Damage IC or TS semiconductor Vertical integrated 7400, check changed resistor 3511 (24k), at the power supply.
PHILIPS 29GX1898/78R
Flashing contrast Check resistor 3460 and capacitor 2462
PHILIPS 29GX1898/78R
Poor contrast Check resistor 3460 and capacitor 2462
PHILIPS 29GX1898/78R
Command only works when the key is pressed directly. Check leaking capacitor 2624
PHILIPS 29GX1898/78R
With dark stripe in the center Tda 8361 for mask n4, run inf 06ct94-18 for gr1-l1
PHILIPS 29GX1898/78R
Turning off flashing Screen darkens every 10 sec. approx. see capacitor line 2456 open.
PHILIPS 29GX1898/78R
LED(s) flashing. (repeatedly) Flashes 6x = check power supply module.
PHILIPS 29GX1898/78R
Thin line in the center (horizontal). Check regulator 7218.
PHILIPS 29GX1898/78R
Lines moving on the screen (vertical). Information psc replace capacitor 2456 for 82pf
PHILIPS 29GX1898/78R
Vertical thin lines. Capacitor 2456, if it is 47pf, change it between values ​​of 56 and 82pf
PHILIPS 29GX1898/78R
Does not accept remote command Check open resistor 3456.
PHILIPS 29GX1898/78R
No characters/menu appear. Check open resistor 3456.
PHILIPS 29GX1898/78R
No characters/menu appear. Check capacitor 2456 (47pf) open
PHILIPS 29GX1898/78R
Does not work (it remains switched off). Check 5445 (flyback).
PHILIPS 29GX1898/78R
Does not work (it remains switched off). Check open resistor 3444.
PHILIPS 29GX1898/78R
Does not work (it remains switched off). Check 7218 (tda7808) open.
PHILIPS 29GX1898/78R
Does not work (it remains switched off). Check power supply control module.
PHILIPS 29GX1898/78R
Does not work (it remains switched off). Check 5441
PHILIPS 29GX1898/78R
Does not work in audio and video Integrated 7225 (tda8361).