Search: philips
Results: 14251
Make Model Symptom Problem Solution By
PHILIPS 4CM5299
Image ok at 640x480 but shifts to the right at 800x600 Replace c2505 3.3 uf by 4.7 uf. located not pine 10 of ic7502 (hef4538 mode detector)
PHILIPS 4CM5299
Image too wide Check bd677
PHILIPS 3CM9609
Dead R3121 (270 k 1 w)
PHILIPS 201B10
No horiz sync when changing resolution C2431 (150 nf 63v)
PHILIPS TAPE-DECK 06AC060
Dead on a channel Ts432a, ts432b, c760 e r606
PHILIPS TAPE-DECK AW-620
Play does not work Ts461 (bc328)
PHILIPS TAPE-DECK AW-620
LEDs off D363 (zener 8,2 v 400 mw)
PHILIPS VR-457/78
Dead open f901 Cp1101 (fuse link icpn15), d955, q901 (2sk2129)
PHILIPS VR-453
Reproduction without color Cold solder on pin 26 of ic601
PHILIPS 3106-106-TX
No vertical deflection C509 (4,7 nf)
PHILIPS 12 TX 1572
Unstable vertical deflection C527 (100 µf 35 v)
PHILIPS TVC/20CT
Dead C355 (470 nf)
PHILIPS R22 K210
Dead Vl603 fuse holder
PHILIPS PT220A
Dead Q7518 (p6na60)
PHILIPS PT220A
Shutter effect Ci7255 (tda4661)
PHILIPS NCF
Does not tune channel C089 (10 nf)
PHILIPS GL1310
Green fabric Cap 0.01 µf short (at pin 26 microprocessor)
PHILIPS GL1045
Dead D345 (zener)
PHILIPS GL1011
Vertical treme C410
PHILIPS CT6000
Flashing luminance C221 (68 µf 25 v)