Sanyo Repair Tips
Search: sanyo
Results: 852
Results: 852
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SANYO |
CTP 6791
|
Dead | R620 120k-1/2w also check r621 | ||
SANYO |
CE28WN4B
|
Procedure to disable protection mode for fault finding | The protection mode can temporarily be disabled to prevent the set going into standby during fault finding by disconnecting r648 note: safety procedures must be followed !! | ||
SANYO |
CBP2580
|
The word "factory" in a red box is permanently displayed on screen and sound volume goes from 0% to 50% to 100% | Enter service mode, go down to nvm and press volume plus on remote | ||
SANYO |
21BN1
|
Dead, l.e.d. lit | R620 o/c. r621 and r620 replaced both 120k | ||
SANYO |
VHR-796E
|
Dead | Pr512 in the psu was o/c | ||
SANYO |
C25EG95B EC3-A25
|
Dead set no start up | Replace r321 120k | ||
SANYO |
CE32WP2 WB2-A32
|
Dead set, standby l.e.d lit | Check capacitor c634 2n2, 2kv in power supply for o/c or s/c | ||
SANYO |
AVM1902 G4S-19020
|
Intermittent horizontal deflection | Resoldered the pins of horizontal deflection transformer | ||
SANYO |
VHR287E
|
Cuts out on record and clock blinks out other wise ok | Replace pr512 js130 light brown 1000 on side near front of psu next to q5103 | ||
SANYO |
VHR766
|
Completely dead, no display | Reg ic511 faulty l5431. replaced solved all problems | ||
SANYO |
CEP2190M
|
No sound | Ic901 tda4935 blown due to excessive supply voltage, capacitors c619, c623, c810, c600, c601, c859 defective. also verify r822 | ||
SANYO |
CEP3011V-30 A1-B14
|
After switching on, no longer able to switch-off with remote control, standby light comes on with sound muted. original remote control: rm-700 | Opto-coupler pc113 faulty | ||
SANYO |
SPECTRA 2000
|
Picture had only wide screen effect | Found set on the street ! beautiful little 14" tv, still looks like new, replaced 33uf, 160v cap in power circuit as it was bleeding its guts onto the pcb, has worked perfectly ever since ! | ||
SANYO |
VHR776E
|
Dead | Check and replace pr512 which is located towards the front right hand side | ||
SANYO |
CTP-3771
|
High power supply | R552 changed | ||
SANYO |
CTP-3792
|
Dark stripe on the right side | Diodo zener-d351-15v | ||
SANYO |
ED1
|
Unable to change chans via front or r/c | Adjust g2 volts - micro tied up due to low emiss crt | ||
SANYO |
ED1 CBP2872
|
No colour | Pvpu2204 chip | ||
SANYO |
ED1 CBP2572
|
Service mode access | 1). press and release memory key (diamond) on front panel. (factory shows on screen) 2). press index/menu key on remote control within 5 seconds. the first tab on the serv.. menu was highlighted allowing me to enter the configuration code (i had been told 02014 was required) directly from the keypad. pressing the remote menu key again changed the on screen display to the next tab heading "geometry" with a list of features ho, so, si, ao, yo, etc............ with the top one ho being highlighted and vertical amplitude and a number written alongside. sure enough operating either vol+ or vol- enabled adjustment of the on screen number and the vertical size of the picture displayed. to alter the next parameter, press the sound button [under the volume + button] to highlight the next tab down. the recommended values are as follows; configuration no. 02014 sets sound intercarrier/standard etc. ho 02140; so 01012; s1 00081; ao 00186 yo 00050; po 15861; zo 01369; p1 01665 z1 00087; sp 00009 | ||
SANYO |
ED1 CBP2572
|
Field collapse at top of screen | C460/461 1000µ 25v, c408 4µ7 50v, ic401 tda8172 & r464 1r 1w |