SANYO CBP2572 ED1
Blank raster no sound no on screen displays . memo Replace or try reprogramming by pressing the service switch and volume plus button together . service switch behind small h
SANYO CBP2565 E3
Dim pic with flaring - ht low Thick film sensing unit faulty - unavailable but a replacement can be made on vero board - power supply tv mag
SANYO CBP2565
Dead - led alight Q724 2sa608 in psu s/c
SANYO CBP2558 E3
It start up &/or shut down - leds stayed on Ic380 12v reg 3122v int o/p & faulty
SANYO CBP2180A A5
Pic shift to left & q422 on dpc pcb overheats Replace line shift pot vr411 50k - cleaning will usually result in call back
SANYO CBP2180A A5
Field non lin, crooked verts & int col 12v supply risen to 14v as ic552 12v reg had dry joint to chassis
SANYO CBP2180A A5
Field - various effects often int Check l451 33mh for o/c
SANYO CBP2180A
St/by only Dry joint r512
SANYO CBP2180A
No pic & txt too far to right - sound ok Hor pos preset (vr404?) - upright, rear left of pcb
SANYO CBP2180A
Field collapse L451 o/c
SANYO CBP2180-00
Int pic Dry joints c554 22µ 250v
SANYO CBP2180 A5-A21
Pic shift to left, hanover bars & no sound Check vr411 hor shift control for o/c
SANYO CBP2180 A5
Field collapse No supply to ic451 fop chip as l451 33µh dry joints or o/c
SANYO CBP2180
St/by only - if st/by button on hset pressed, led would go out only to reappear a few secs later No 12v supply - ic552 78m12 reg o/c
SANYO CBP2180
Sound buzz, non lin field & lines Crack in print by field chip heatsink so c451 had no chassis return
SANYO CBP2180
Pic displaced with vert band of col or no sound - osd ok Vr411 hor shift pot
SANYO CBP2180
No tuning or tuning volts R714 10k on front control pcb o/c
SANYO CBP2180
No signals No volts at tu pin of tuner - dry joints link j159 at front right of main pcb
SANYO CBP2180
Intermittent dead Dry joints on q432
SANYO CBP2180
Int lum Dry joint lum del line io21 near loptx