SANYO |
CBP2180
|
Field bounce | L401 in field o/p supply intermittent | ||
SANYO |
CBP2168
|
No front controls so no tuning possible - r/c ok | D710. 711 6v2 zeners leaky on main pcb | ||
SANYO |
CBP2168
|
Int goes blank raster & no sound | Check 5v st/by supply present - sus st/by tfmr pri | ||
SANYO |
CBP2162 E4
|
No pic - sound ok - blank raster when a1 advanced | Low amplitude scastle pulse pin 27 - ic101 tda4505m faulty - first check 12v supply at pin 7, if low then sus ic362 l78m12-ra 12v reg | ||
SANYO |
CBP2162 E4
|
Blank raster with sound | Tda4505m ic101 | ||
SANYO |
CBP2162
|
Int dead then perm dead | Ht present with snowy raster when a1 advanced - no r/c functs. no 5v to micro - st/by trfmr o/c pri | ||
SANYO |
CBP2162
|
Field non lin | Tda4505m - tried "e" suffix but would not work in spite of changing res | ||
SANYO |
CBP2152 E4
|
Dead - will briefly come out of st/by | Ht ok at lop - no line drive as 12v supply to pin 7 tda4505 was low; ic362 l78m12 reg chip faulty | ||
SANYO |
CBP2152
|
No pic for 1min then comes on all white for 30secs | Tda3566 us ( pal ntsc ) | ||
SANYO |
CBP2152
|
Int stuck in stby also int random channel change | D674 6v2 zener other diodes in cct may cause similar faults | ||
SANYO |
CBP2152
|
Int failure to come out of st/by & random chan change | D746 6v2 zener between front panel & 'tac' switch | ||
SANYO |
CBP2148
|
St/by only | Momentary contacts on mains sw - should make b4 mains contacts | ||
SANYO |
CBP2147
|
St/by only | Fault in st/by cct - linked st/by conn on mains sw to chassis but no st/by facility now available | ||
SANYO |
CBP2146 E2-E21
|
Poor sync. | Ic1011 ( saa5230 ) | ||
SANYO |
CBP2146 E2-E21
|
Picture fades shortly after switch on. | Sprinkle r479. | ||
SANYO |
CBP2146 E2-E21
|
Lack of width and shuts down when set is warm. | C310 ( .047uf 50v ) | ||
SANYO |
CBP2146 E2-E21
|
Int red picture. | Drys a602 on crt base. | ||
SANYO |
CBP2146 E2-E21
|
Corrupted text. | Ic1031 ( saa5240a ) | ||
SANYO |
CBP2146 E2-E21
|
Corrugated verticals. | Check eht lead connections. | ||
SANYO |
CBP2146 E2-E21
|
Bright raster with flyback lines. | R478 ( 10k ) o/c. |