Search: sanyo
Results: 852
Make Model Symptom Problem Solution By
SANYO CBP2876
Red, green & blue flyback lines C700 100µ hi esr
SANYO CBP2872 ED1
No sound when sw on if still warm Ic560 adc2301e on sigs panel pt no 409 211 9404
SANYO CBP2872 ED1
No sound - comes on briefly when cold sometimes with crackle/hiss Ok from scart socket - ic561 apu2471 could be faulty
SANYO CBP2872 ED1
Lines when cold with shading as warms up C404 (100mfd 50v) in the frame stage was the culprit, although its esr reading was ok, and there were no signs of leakage
SANYO CBP2872
Repeat fail of lop tr ( 2sd1555 ) Ic dpu2553
SANYO CBP2872
No sound from spkrs - ok from scart Ic561 apu2471 on sigs panel
SANYO CBP2866
Int trip/blank raster/no field sync Ic780 12v reg - use tip41 & 13v zener & 27v dropper as reg nla
SANYO CBP2865 E3A28
Picture and sound goes off int. 12v reg ic780 failed when hot.
SANYO CBP2865 E3
Int sound/pic with bright white raster with low height or field collapse reverting to st/by Ic780 si3122v 12v reg s/c internally when heated
SANYO CBP2865
Int bright raster with reduced height Replace ic780 12v regulator
SANYO CBP2580A EB2 SERIES
Tripping - even with psu on dummy load Black jumper wire which runs from the earth side of the chopper transformer to a point very close to ic351 a regulator ic, was dry jointed at the chopper transformer end.
SANYO CBP2580 EB125
This set would shut down interrnittently: the peri The set could be made to run indefinitely by entering the service mode ( menu on the set's control panel , followed by menu on
SANYO CBP2580 EB1
To enter service mode Menu on set's control panel, followed by menu on r/c handset
SANYO CBP2580 EB1
Shuts down int - runs ok in service mode if im bus run is stopped Fault somewhere on the im bus - nvm3060 eeprom on digiboard cured fault
SANYO CBP2580 EB1
Colour lost & pic shifted to right when heated Xtal x403 pt no 610 217 1037
SANYO CBP2580 EB1
After 2-3 hrs colour goes and picture shifts to r Xtal x403 drifting pt no 610 217 1037
SANYO CBP2580
St/by only - trips at start up 22mfd 250v b+ decoupler s/c
SANYO CBP2580
Int start up - eht can be heard Check for int mains switch
SANYO CBP2576A/00
Bright blue raster with fb lines Ic500 which is a tea5101a on the crt base pcb. r534 22Ω was ok.
SANYO CBP2576A ED0 CHASSIS
No raster Tea5101a rgb chip