SHARP C-2013
Doesn't work R 725, Rahat, Rahat, crossed This email address is being protected from spambots. You need JavaScript enabled to view it.
SHARP 20R11
No color Resistor r839 - 47k altered, r830 - 39k altered Replace the resistors marcius melo (This email address is being protected from spambots. You need JavaScript enabled to view it.)
SHARP C-1438
Does not turn on, normal power supply, normal 120v C 726 without capacitance pardalzito
SHARP C2025A
Vertical closed C512
SHARP C-1457
...
It takes a long time for the image to appear AC voltage supplying the kinescope filament very low. Take about 35 cm of number 8 wire, turn the fly-back ferrite 4 times, remove the original filament connection; and connect and connect the wire that was wound on the ferrite on the kinescope filament...pin 4 and 5...ok. Armando
SHARP C-2053
Doesn't start Resistor 731 Resistor 731 1r alexandre guimaraes
SHARP TVC 1686
After some time, the image begins to close the frame, leaving it half full. Chap. tantalum - c 512, critical value, replace. Luna
SHARP TVC 1417
It doesn't turn on and it makes noise on the flay black C 617 shorted C 617 replace osmar
SHARP C14R12
Doesn't start C616 Edmilson C Castro
SHARP C-2041
No contrast opaque image R423 ( 680k ) aberto proximo´s fabiusmax
SHARP TV C- 2041 B
TV works but with half screen, vertical closes from bottom to top. Trcado o c- 1/100 volts jaironuness
SHARP C- 20S57
TV works as if everything were weak, in the background you can see retrace lines. Replaced c 624 c 603 jaironuness
SHARP C-2013
Normal sound dark screen Fly back and tube socket before exchanging them, measure the screen voltage if it is normal to just change the socket. This email address is being protected from spambots. You need JavaScript enabled to view it.
SHARP C-2013
Normal sound dark screen Fly back and tube socket before exchanging them, measure the screen voltage This email address is being protected from spambots. You need JavaScript enabled to view it.
SHARP C2041 B
Image without contrast, when the screen decreases the image oscillates R612-27k open paulorusso
SHARP 20R12
No characters R 1047 of 33k open Daniel
SHARP C20R12
******
Image without contrast, very dull. ****** Trick....clean pin 14 (turn off) and that's it armando
SHARP C 2057
C 2057
It takes a while for the image to appear with a weak tube symptom Capacitor c624 3,3mf 50v proximo diodo d601 Edson Peixoto
SHARP C2038
Alloy has but b of the power supply but does not oxidize C.725.47mf.por.160v julio itaguai
SHARP C20T51