Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CDPCX153
|
No display - broken taxes on display board # 69 | No display. | ||
SONY |
CDPCX153
|
Disc is scraping on chucking assy when playing | The disc may be scarping on chucking assy when playing. | ||
SONY |
CDPCA7ES
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
CDPCA7ES
|
Will not load, no platter rotation - replaced m801 | Units exhibit a variety of loading symptoms. all are dueto the rotary table not turning. problem is caused by rotary table motor, m801. | ||
SONY |
CDPC90ES
|
Not reading cd's intermittently - replaced d601/602 | Unit would not read cd's intermittently, and would damagecd's. found unit would intermittently not see that there was a disc. thiswould happen particularly in discs 1,2 & 10. | ||
SONY |
CDPC545
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
CDPC445
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
CDPC435
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
CDPC335
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
CDPC245
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
CDPC235
|
Tray motor not labeled or wired correctly | After replacing the tray motor with a new one the playerwould not work correctly, the tray would rotate back and forth and notrecognize the cd in the unit. | ||
SONY |
XRU220
|
Key switches fail | There seems to be a problem with the volume + switches withall xru, cdx5180 and cdxu8000 units. i have repaired ten units of variousmodel numbers over the past three months. some have been returns with thenewly replaced switch broken. is this a switch | ||
SONY |
CDX51RF
|
Wired remote commander part numbers not in service manual | The manual does not show any part numbers for the wiredremote commander supplied with the rf version. most of the parts areidentical to those found in the cdx-45rf manual, so the technicians orderparts from that manual. but in the case of the front pan | ||
SONY |
CDX5180
|
Certain function buttons are inoperative (replace switches) | Some of the function buttons do not work properly. | ||
SONY |
GEN-CAM
|
Lanc jig hardware component value changes - d3, d4, r1 | Two incorrect diodes were installed in the lanc jig. thisaffects 100 units and should be checked and corrected if necessary. | ||
SONY |
GEN-CAM
|
Lanc jig software update version 2.1b now available | An update to the lanc jig software is now available. the newversion is 2.1b. | ||
SONY |
WMFS495
|
Intermittent operation | Unit has intermittent operation. audio cuts in and outintermittently. | ||
SONY |
MZE2
|
Difficulty loading/playing when vertical | Found 3 units which had difficulty loading and/or playingdiscs when the unit was in the vertical position. problem appears to becaused by dead spots on the sled motor (m902), which causes the motor tostop working when more driving force is needed. | ||
SONY |
SLVR1000
|
Auto tracking light flashing for a long time replace c106 | All functions appeared to be normal, except auto tracking. light flashes for a long time before stopping temporarily, only to start flashing again. | ||
SONY |
SLV940HF
|
Switching point off - adjusted ent. guide plate | Looks like head switching problem. |