Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CCDTR93
|
Viewfinder inoperable/input data in page "d" add's bo to bb | No color in viewfinder. | ||
SONY |
CCDTR83
|
Lens cover opens part way / rpl panel assy, front | Lens cover only opens half way. leakage problem on frontpanel/nosepiece. one dealer reports seeing 3 units with this problemrecently. - solution: replacing cab assy, fnt (nose piece) solves problem. | ||
SONY |
CCDTR83
|
No pix camera mode / resldr x701 off timing gen ic702 | No picture in evf or line out during camera mode, justflickering and noise. found oscillator at timing generator ic702 coldsoldered, producing erroneous frequency. | ||
SONY |
CCDTR83
|
No pix in vf / resld cn203 on vs board | No pix in playback and rec. | ||
SONY |
CCDTR83
|
No playback pix / replace c1167 on the he19 bd | No playback pix, audio ok. | ||
SONY |
CCDTR83
|
Intermittent creases tape / replace pinch roller | Found unit intermittent creases tape on playback and rec.pinch roller caused problem. | ||
SONY |
CCDTR83
|
Jack cover comes off by itself. | Jack cover comes off by itself, models ccdtr367376/83/93 andtr100 affected. saw 5 units with same problem.- solution: replace cover, jack- hq comments: japan is aware and is working on a fix. | ||
SONY |
CCDTR81
|
Not loading with tape / replace cassette assy | Unit loading without the cassette holder and when tape insidecassette holder, without the tape the unit loads half way then ejects.found cassette holder bad. | ||
SONY |
CCDTR81
|
Bend on top of pix in camera mode/replace ic401 (y process) | Bend on top of pix in camera mode. bent more when there isa lot of light on subject. when pointed down or covering lensabove a few inches by hand or paper you could see a little bend in pix.playback ok. | ||
SONY |
CCDTR80
|
Individual motor testing using rm-95 | Models such as the ccdtr400 and ccd fx430 do not include the motor test on one of the service procedures, ex, capstan forward andreverse drum forward and reverse etc. | ||
SONY |
CCDTR80
|
No color on record or playback / replace x201 | Camera had no color through the monitor, but pix in evf wasok. discovered frequency of vxo 40 hz lower. | ||
SONY |
CCDTR73
|
No pix camera mode / resldr x701 off timing gen ic702 | No picture in evf or line out during camera mode, justflickering and noise. found oscillator at timing generator ic702 coldsoldered, producing erroneous frequency. | ||
SONY |
CCDTR73
|
No pix in vf / resld cn203 on vs board | No pix in playback and rec. | ||
SONY |
CCDTR73
|
No playback pix / replace c1167 on the he19 bd | No playback pix, audio ok. | ||
SONY |
CCDTR73
|
Viewfinder inoperable/input data in page "d" add's bo to bb | No color in viewfinder. | ||
SONY |
CCDTR71
|
Dead / lit bat reset | Unit came in dead, has display no batt indicator, nofunctions. -solution :removed lith batt ran unit then reinstalled lith batt. letsit overnight, still worked next am. have seen this in 2 other ccdtr71,is there amod like in the fx series for lockup | ||
SONY |
CCDTR700
|
Colors are changing / zero out data, page "f" add 6b; was f1 | After comparing data with a working unit, found address 6b ofpage f to be f1 (awb all tracking mode), changed data to 00 to restorethe normal mode of awb operations. | ||
SONY |
CCDTR700
|
Dist/low audio on left channel / repl d519 on the jk-108 bd | Unit had very low and distorted audio on the left channel. | ||
SONY |
CCDTR700
|
Dead / replace f450 & f452 | Unit not powering on vtr/camera. found f450, f452 badcaused by drop of unit. unit also has bend in cassette holder and brokenpart caused by impact of drop. | ||
SONY |
CCDTR700
|
Cassette holder not closing / replace slider (t) assy | Cassette holder is not closed and that's why the unit cannotaccept tape. found plate assy side broken caused by a drip. -solution :replace (t) assy side. |