Make Model Symptom Problem Solution By
SONY CDPC665
Drawer won't open - secured loose sensor board Drawer won't open, carousel jammed over disc table. foundsensor board was never screwed down. board came loose and jammed mech,damaged components.
SONY CDPC545
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with label facing up, motor will spin backwards andtray will not function properly.
SONY CDPC535
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with label facing up, motor will spin backwards andtray will not function properly.
SONY CDPC445
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with label facing up, motor will spin backwards andtray will not function properly.
SONY CDPC435
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with label facing up, motor will spin backwards andtray will not function properly.
SONY CDPC345
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with lable facing up, motor will spin backwards andtray will not function properly.
SONY CDPC345
Cd drawer takes minutes to open - replaced ic451 Drawer took several minutes to open. found drawer would spinendlessly.
SONY CDPC245
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with label facing up, motor will spin backwards andtray will not function properly.
SONY CDPC245
Disc table won't stop - replaced m801 Disc table rotates continuously and cd player won't' detect discs. replaced flex cable and checked d801 sensor, player is still doing same thing.
SONY CDPC235
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with label facing up, motor will spin backwards andtray will not function properly.
SONY XRU330
Unit will not turn on (replaced leaky d202 and d203) Unit will accept the tape and play but once turned off can notturn it on.
SONY XRU220
Unit will not turn on (replaced leaky d202 and d203) Unit will accept the tape and play but once turned off can notturn it on.
SONY XRC720
No audio (found audio amp ic781 defective) No audio. found audio amp ic781 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XRC620
No audio (found audio amp ic781 defective) No audio. found audio amp ic781 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XRC610
No audio (found audio amp ic781 defective) No audio. found audio amp ic781 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XRC520
No audio (found audio amp ic901 defective) No audio. found audio amp ic901 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XRC410
No audio (found audio amp ic901 defective) No audio. found audio amp ic901 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XRC210
No audio (found audio amp ic901 defective) No audio. found audio amp ic901 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XRC190
No audio (found audio amp ic901 defective) No audio. found audio amp ic901 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off
SONY XR6450
No audio (found audio amp ic901 defective) No audio. found audio amp ic901 defective. -hq comments: tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the ic, probably by the power antenna relayturning off