Sony Repair Tips
Search: sony
Results: 20073
Results: 20073
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CCDTR73
|
No pix in vf / resld cn203 on vs board | No pix in playback and rec. | ||
SONY |
CCDTR73
|
No playback pix / replace c1167 on the he19 bd | No playback pix, audio ok. | ||
SONY |
CCDTR73
|
Viewfinder inoperable/input data in page "d" add's bo to bb | No color in viewfinder. | ||
SONY |
CCDTR71
|
Dead / lit bat reset | Unit came in dead, has display no batt indicator, nofunctions. -solution :removed lith batt ran unit then reinstalled lith batt. letsit overnight, still worked next am. have seen this in 2 other ccdtr71,is there amod like in the fx series for lockup | ||
SONY |
CCDTR700
|
Colors are changing / zero out data, page "f" add 6b; was f1 | After comparing data with a working unit, found address 6b ofpage f to be f1 (awb all tracking mode), changed data to 00 to restorethe normal mode of awb operations. | ||
SONY |
CCDTR700
|
Dist/low audio on left channel / repl d519 on the jk-108 bd | Unit had very low and distorted audio on the left channel. | ||
SONY |
CCDTR700
|
Dead / replace f450 & f452 | Unit not powering on vtr/camera. found f450, f452 badcaused by drop of unit. unit also has bend in cassette holder and brokenpart caused by impact of drop. | ||
SONY |
CCDTR700
|
Cassette holder not closing / replace slider (t) assy | Cassette holder is not closed and that's why the unit cannotaccept tape. found plate assy side broken caused by a drip. -solution :replace (t) assy side. | ||
SONY |
CCDTR70
|
Individual motor testing using rm-95 | Models such as the ccdtr400 and ccdfx430 do not include themotor test on one of the service procedures, ex, capstan forward andreverse drum forward and reverse etc. | ||
SONY |
CCDTR70
|
No color on record or playback / replace x201 | Camera had no color through the monitor, but pix in evf wasok. discovered frequency of vxo 40 hz lower. | ||
SONY |
CCDTR61
|
Slow/poor af when changing zoom position / clean zoom pot | Received a number of reports from best buy of slow/poorautofocus when changing the zoom position of the lens. problem due todirty zoom potentiometer. dirty control does not provide correct feedbackto the cp. auto focus program does not run correctly. | ||
SONY |
CCDTR61
|
No camera chroma / l721 open | No cam c signal present at pin 12 of w405 on vc133 board.good cam c singal at pin 30 of ic707 camcore. | ||
SONY |
CCDTR600
|
No pix camera mode / resldr x701 off timing gen ic702 | No picture in evf or line out during camera mode, justflickering and noise. found oscillator at timing generator ic702 coldsoldered, producing erroneous frequency. | ||
SONY |
CCDTR600
|
No pix in vf / resld cn203 on vs board | No pix in playback and rec. | ||
SONY |
CCDTR600
|
No power and drum spins faster than normal/resld ic505 | Dead, no power drum spins faster than normal. | ||
SONY |
CCDTR600
|
No playback pix / replace c1167 on the he19 bd | No playback pix, audio ok. | ||
SONY |
CCDTR600
|
Jack cover comes off by itself. | Jack cover comes off by itself, models ccdtr367376/83/93 andtr100 affected. saw 5 units with same problem.- solution: replace cover, jack- hq comments: japan is aware and is working on a fix. | ||
SONY |
CCDTR600
|
Viewfinder inoperable/input data in page "d" add's bo to bb | No color in viewfinder. | ||
SONY |
CCDTR6
|
No audio intermittent audio e-e / replace c469 | No e-e audio. found voltage low pin 42 ic401. should be2.1 v it was .7 volts. found c469 220pf 50v tantalum capacitor leaky.thus allowing microphone audio to appear at pin 42 but pulling down thedc voltage at that pin and activating the mute circuit | ||
SONY |
CCDTR6
|
Loss of atf / l502 open | Picture would intermittently lose tracking, and the tracking lines from scan would roll through picture no atf. |