SONY MDS101
Unit stuck in standby mode - re-position jammed eject switch Unit stuck in standby. eject button constantly depressed.
SONY MDS101
Would not eject disc - repl missing washer, ref.# 52 Unit would not eject disc. washer on top left cover of sliderassy missing, which misaligned mech and made disc sit incorrectly.
SONY HCDH150
No power - replaced +5v regulator and zener d735 No power.
SONY HCDC50U
Cd loading too fast - replaced ic414 Travels to fast causing cd's to shift out of tray.
SONY HCDC33
Unit flashes initializing - cd section needs alignment When power plug is pulled out and plugged back in unit flashesinitializing on display until cd mech cycles through all drawers. if cddoes not cycle due to a jam, the unit will not come out of theinitializing cycle. unit will turn on but when it is powe
SONY HCDC33
Cd jammed - realigned mechanism Mechanism jammed. trays 333-337 slide into main tray, 310, inthis case tray 337 did not latch into 310 causing the mech to jam.
SONY DTC700
New slant block assy left/right not working Upon installation of the new slant block assy, left/right,they are not sliding freely in the slot on the chassis. when screw 628 istightened in place with ref 606, plate assy, loading, the two pieces arepinched together.
SONY DTC59ES
Eats tapes - tightened capstan mount screws Unit eats tape at beginning of 120 min. tape in long mode.found tape would ride down on capstan.
SONY CDPC615
No tray rotation or bu assm chucking - repl flex cable Tray would never rotate. bu assm would never chuck.
SONY CDPC335
Tray motor spinning backwards - replace table motor Ran into this problem 5 times in past 3 weeks. removed traymotor. old motor is installed with lable on motor facing up. if newmotor is installed with lable facing up, motor will spin backwards andtray will not function properly.
SONY CDP590
Incorrect part # j401 - correct part #156692111 The microfiche service infomration gives j401 as part #1-569-442-11. this is incorrect.
SONY XRU880
Dead unit (replaced q504 and d513) Unit was dead. master control ic was on but would not powerup unit (pin 5 stayed low). bus on pin 38 would pulse low 3 times whenunit was powered up. data and clock lines would show initial activity.
SONY XRU770
Dead unit (replaced q504 and d513) Unit was dead. master control ic was on but would not powerup unit (pin 5 stayed low). bus on pin 38 would pulse low 3 times whenunit was powered up. data and clock lines would show initial activity.
SONY XRC410
Mechanism gear alignment procedures available in supp. #1 The mechanism in this model uses gears and encoders which mustbe aligned properly in order for the mechanism to work, but the manualdoes not detail the alignment procedure.
SONY XRC210
Mechanism gear alignment procedures available in supp. #1 The mechanism in this model uses gears and encoders which mustbe aligned properly in order for the mechanism to work, but the manualdoes not detail the alignment procedure.
SONY CDX5470
Optical pickup received from npc does not work in unit The unit came in for service with type kss-410a opticalpickup, which was defective. the type shown in the service manual iskss-313a, which was ordered from npc and installed in the unit, but thispickup did not work in the customer's unit. is there a pa
SONY CDX5270
Optical pickup received from npc does not work in unit The unit came in for service with type kss-410a opticalpickup, which was defective. the type shown in the service manual iskss-313a, which was ordered from npc and installed in the unit, but thispickup did not work in the customer's unit. is there a pa
SONY CDX5070
Optical pickup received from npc does not work in unit The unit came in for service with type kss-410a opticalpickup, which was defective. the type shown in the service manual iskss-313a, which was ordered from npc and installed in the unit, but thispickup did not work in the customer's unit. is there a pa
SONY CDX45
Discs don't spin, "e04" shown on display (replaced ic13,q21) Loads the cd but will not spin, shows e04 on display.
SONY CDV701
Most function buttons do not operate/check eject button Most of the function switches do not operate. a selected fewwill respond. unit resembled having a button stuck in the activated mode. i was not able to track this down by checking key scan lines to and fromthe micro. i was able to determine the fault