Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CDX5470
|
Optical pickup received from npc does not work in unit | The unit came in for service with type kss-410a opticalpickup, which was defective. the type shown in the service manual iskss-313a, which was ordered from npc and installed in the unit, but thispickup did not work in the customer's unit. is there a pa | ||
SONY |
CDX5270
|
Optical pickup received from npc does not work in unit | The unit came in for service with type kss-410a opticalpickup, which was defective. the type shown in the service manual iskss-313a, which was ordered from npc and installed in the unit, but thispickup did not work in the customer's unit. is there a pa | ||
SONY |
CDX5070
|
Optical pickup received from npc does not work in unit | The unit came in for service with type kss-410a opticalpickup, which was defective. the type shown in the service manual iskss-313a, which was ordered from npc and installed in the unit, but thispickup did not work in the customer's unit. is there a pa | ||
SONY |
CDX45
|
Discs don't spin, "e04" shown on display (replaced ic13,q21) | Loads the cd but will not spin, shows e04 on display. | ||
SONY |
CDV701
|
Most function buttons do not operate/check eject button | Most of the function switches do not operate. a selected fewwill respond. unit resembled having a button stuck in the activated mode. i was not able to track this down by checking key scan lines to and fromthe micro. i was able to determine the fault | ||
SONY |
CCDTR82
|
No steady shot | No steady shot indicator showed in viewfinder. | ||
SONY |
CCDTR77
|
No camera output/resolder l710 | The camera had no output. the problem was caused by l710 onthe vc136 board being poorly soldered on one side. re-soldering resolvedthe problem.l 710 is in the camera 5v line. when it opens the camera sections isbasically dead. | ||
SONY |
CCDTR71
|
Only zooms one way/replace ic855 | Unit would only zoom in the direction that zoom was firsttried at power-on. if you tried wide first, it would only zoom wide untilyou turned power off. after killing power if you tried tele first, wouldonly zoom in the telephoto. | ||
SONY |
CCDTR71
|
Broken view finder latch | View finder latch breaks off and you must replace (or at leastorder) the entire right cabnet to fix it. can the latch be made aseperate part number? -hq comments: we investigated this before, and found it to be tooexpensive to get a sufficient quantity | ||
SONY |
CCDTR70
|
New vc-145 does not work change page f add 00 to data 5e | New vc-145 does not work | ||
SONY |
CCDTR7
|
Loses y signal after a few minutes/replace c318 | Would lose y signal after unit was on for a few minutes. | ||
SONY |
CCDTR400
|
Noisy capstan, intermittent rotation/replace capstan motor | Noisy capstan, intermittent rotation. | ||
SONY |
CCDFX620
|
Part number for tele/wide switch incorrect/1-692-257-21 | Drawing in s/m is incorrect showing plug in flex connector andswitch board. flex board is actually part of switch assy. | ||
SONY |
CCDFX530
|
Drum problem/resolder ic505 | Drum assy runs extremely fast. | ||
SONY |
CCDFX530
|
No focus, no zoom/replace lens block | No focus, no zoom | ||
SONY |
CCDFX510
|
Premature tape end detection | We need clarification on csv-3 service bulletin #333. the partlisted as c865 is a filter cap on the focus motor b+ line on p.116. thedrawing in the s/b shows c559, which is a filter on 5v regulator ic508 onp.122. which cap should be changed for this symp | ||
SONY |
CCDF55
|
Japanese characters for month on osd, lcd display ok | Due to water damage, we had to replace the ct21 board on thisunit. after installation, we could not get the osd to display the datecorrectly. either it was yy/mm/dd or mm/dd/yy, but with the month injapanese characters. | ||
SONY |
GDM17SE1
|
Screen slowly disappears check c625 on the g-board | The symptom of screen slowly diappearing was caused by c625failure. -hq comments: thank you. please see bulletin 70. | ||
SONY |
CPD15SF1
|
Misconvergenge caused by a board shield case (degauss case) | |||
SONY |
CPD15SF1
|
Intermittent focus problem, degaus crt neck with unit on | Focus changes intermittently. -hq comments: degauss a crt around the neck area while the unit is in the on position. this may remove the problem. if this fails to work,replace the picture tube. |