Search: sony
Results: 20072
Make Model Symptom Problem Solution By
SONY KV27XBR15
ANU1
Dead Sony kv27xbr15 anu-1 chassis unit is dead. unit had all 3 regulators loose. all had ring fractures. once resoldered the set still did not turn on because of a short to ground on the 135 vdc line. Horizontal output is also shorted. ?this unit requires a modification to the horizontal output section kit # t-998-56641. this kit consists of a 2sc4927 and a .68Ω resistor that must be used in the emitter of the horizontal output transistor. Muller
SONY KV32XBR10
ANU1
Audio Unit has no audio 8-741-592-2 (8-741-100-56) original number sbx1592-02 corrected the symptom Muller
SONY KV27TS20
ANU
Vertical Kv27ts20 unit has highly intermittent vertical foldover mostly at the top of the screen Unit had small ring fractures around the vertical deflection yoke connector pins on the chassis. resoldering the connections corrected the symptom Muller
SONY KV32V26
AA3
Green retrace lines Sony kv32v26 serial 8012582 goes to green retrace lines and then shuts down. when it comes back on again the unit will be in the video input mode. The crt # is a80jyv51x . the cathode voltages at red and blue cathodes are 156 but the green cathode is 22. when the socket is disconnected the green cathode supply jumps to 153 vdc. the crt is defective. Muller
SONY KV36XBR250
AA-2W
Geometry Kv36xbr250 this television has as symptom on the screen wsound a small area has a non linear horizontal area that causes the image to expand when the image passes through this area. the area about 1/2 inch wide and effect the entire frame of the picture. it can be seen if characters are scrolling through the screen. Tech needs to replace the value of c553 from .33 @ 200 vdc to .47 @ 250 vdc part number 1-117-667-71. this improve the linearity in that are of the screen Muller
SONY KV36XBR250
AA-2W
16x9 mode Customers dvd player always plays back in 16x9 mode. customer has jvc dvd player. disc plays back in 16:9 customer selects 4x3 mode on their dvd player but tv stills displays 16x9. the jvc dvd player puts out id signal even when no 16x9 is available. when the sony tv detects this special id signal it automatically puts the tv in to the 16x9 mode. compression mode. customer must now select modes manually on their dvd player. This auto feature can be turned off but only in the service mode. replace id7 from 9 to 8. this is the no auto v. customer must now select modes manually on their dvd player. Muller
SONY KV36XBR200
AA-2H
Vertical sweep Kv36xbr200 serial 9015396. unit has insufficient vertical sweep. also has top vertical foldover. tech can get into the menu and effectively move the vertical height and centering but it will not illuminate the foldover condition Tech needs to replace ic561, d561, & c565 Muller
SONY KV36XBR20 0
AA-2H
Vertical Unit has insufficient vertical sweep. also has top vertical foldover. tech can get into the menu and effectively move the vertical height and centering but it will not eliminate the foldover condition. Tech needs to replace ic561, d561, & c565. unit had defective pump up capacitor. c565 Muller
SONY KV36XBR200
AA-2H
Screen temperature Kv36xbr200 serial 9016329. on the far extreme left and right side of the screen the picture has a yellow color temperature wsound it should be white. When looking at a blue raster at 60 ire the blue does not have uniform brightness across the screen. the light output is not the same level at the area of the screen wsound we see the yellow with a 60 ire white screen. we are not able to adjust the blue to make it equal in brightness in all areas of the screen.. this is a defective crt. customer does not want the set requesting a replacement. under 30 day Muller
SONY KV36XBR200
AA-2H
Geometry Kv36xbr200. serial 9016768. "" unit has pincushion error o the top of screen. area around the extreme edges of the fields do not have straight lines. horizontal lines have a shoulder roll off. tech ordered yoke specific to bulletin # 387 , but received the complete crt. i held off replacing the crt due to three of these have been changed so far with no changes in the symptom "" Bulletin 387 did not mention a thl plate which needed to be adjusted was in the old deflection yoke. after following the new bulletin 387r1 we were able converge the set. also the new tube needed 3 magnetic on the bell of the tube to correct a purity error and converge the lower right hand corner. Muller
SONY KV36XBR200
AA-2H
Geometry Kv36xbr200 picture is tilted. tsound is insufficient range in the tilt adjustment Use part number out of bulletin 379 for the pix tilt correction coil. Muller
SONY KV36XBR20 0
AA-2H
Focus Kv36xbr200 serial 9023068out of focus on the extreme horizontal edges of the screen. the last 3 inches have a noticeable focus error Crt...attempting to move the focus control does not cause the area on the outside of the crt to replace focus. unit may have bad crt. Muller
SONY KV36XBR200
AA-2H
Arcing Kv36xbr200 unit has an intermittent arc over that will shut down the television. The best way to tell if the arcing is related to the hv lead which may be breaking down is to use a high voltage probe. connect the ground to the crt ground and run the tip of the high voltage probe over all high voltage connections & wires. if an arc is drawn to the probe tip this would mean that a break down in the insulation has occurred. this test revealed a break down in the high voltage connection at the high voltage anode button. the silicone sealant did not seal between the hv button and hv cup. cleaning the area around the anode button, replacing the anode cap and resealing the connection with high voltage silicone sealant. Muller
SONY KV32FV1
AA2H
Tuning Kv32fv1 serial 9002390 main tuner will not tune any channels but the pip tuner is fine. tuner was changed without any change in the symptom. set just displays snow on all channel from the main tuner and the osd for main channel display is normal. I had tech check the b+ on the tuner that are stamped on the board. the 9, 30 & 5 volts are normal. the scl line is only 2 volts and the sda line is 4.6. the scl line is the trouble. tech did not have an oscilloscope but since the scl line for this tuner is the same for the pip tuner we concluded the cpu was not at fault. tsound appeared to be an open between the scl of the main tuner and cn1101(6). since the traces on the cba are so thin the and no cracks in the board material could be seen the decision was to install a small jumper wire between these two points. this corrected the Muller
SONY KV32FV1
AA2H
Remote Unit does not operate with remote control. front panel controls are operating ok. Unit has ""0"" volts on the output of the ir receiver ic2001(1) this should be 5 volts as long as it is not receiving data. customer has an rca dvd player connected using the s-video input and the s-link too. sony's s-link is not compatible with rca's g-link input used to control operational functions. disconnect the s-link / g-link connections and restored operations. "" Muller
SONY KV32FV1
AA2H
Remote Kv32fv1 unit does not operate with remote control. front panel controls are operating ok Unit has ""0"" volts on the output of the ir receiver ic2001(1) this should be 5 volts as long as it is not receiving data. customer has an rca dvd player connected using the s-video input and the s-link too. sony's s-link is not compatible with rca's g-link input used to control operational functions. disconnect the s-link / g-link connections and restored operations "" Muller
SONY KV32XBR200
AA2H
No high voltage Kv32xbr200 9015636 unit will click on then it will turn off again. does not get high voltage. Unit has b+ to horizontal output but no horizontal drive. if the horizontal output is removed the set will produce the necessary drive signals. collector of h. driver q501(c) measures 85 with horizontal output removed. unit appears to have a shorted flyback or a problem in the horizontal output section that caused the ocp circuit to attack. product had a defective flyback transformer. Muller
SONY KV36FV1
AA2H
Geometry Kv36fv1 serial . unit has shoulder roll off on the screen. Gave tech bulletin #387 for the yoke upgrade Muller
SONY KV32XBR200
AA2H
Geometry Kv32xbr200 unit has just had the new crt with the attached yoke replaced today to correct the shoulder roll off symptom as described in bulletin 387r2. however the new tube and yoke did not solve the vertical pincushion symptom See bulletin #387r1 Muller
SONY KV32XBR200
AA2H
Geometry Kv32xbr200 unit has just had the new crt with the attached yoke replaced today to correct the shoulder roll off symptom as described in bulletin 387. however the new tube and yoke did not get installed. instead we are going to contact sony Bulletin 387 did not mention a thl plate which needed to be adjusted was in the old deflection yoke. after following the new bulletin 387r1 we were able converge the set. also the new tube needed 3 magnetic on the bell of the tube to correct a purity error and converge the lower right hand corner. Muller