SONY KV35V68
AA-2
Tv guide plus Tv guide plus does not function. when the television is setup for tv guide plus the customer is selecting that they have a vcr and catv box. but they are not using the cable mouse or ir blaster. The ir blaster is used to communicate from the television to the catv box in order for downloading to occur. if the ir blaster is not used the feature will remain inoperable because when the set downloads the data, it must find the host channel. it uses the ir blaster to replace channels on the catv box in order to find the host channel. in order for this to operate the customer must use the ir blaster. if not they will need to split the cable before it gets to the catv box and deselect any vcr or catv box questions by answering ""n0"" to questions about them in the initial setup menu. "" Muller
SONY KV35V68
AA-2
Tv guide plus Kv35v68 serial 9005526 tv guide plus does not function. when the television is setup for tv guide plus the customer is selecting that they have a vcr and catv box. but they are not using the calble mouse or ir blaster. The ir blaster is used to communicate from the television to the catv box in order for downloading to occur. if the ir blaster is not used the feature will remain inoperable because when the set downloads the data, it must find the host channel. it uses the ir blaster to replace channels on the catv box in order to find the host channel. in order for this to operate the customer must use the ir blaster. if not they will need to split the cable before it gets to the catv box and deselect any vcr or catv box questions by answering ""n0"" to questions about them in the initial setup menu. "" Muller
SONY KV36FS10
AA-2
System control Unit will turn on but not have any raster until the channel is selected. the led in front flashes indefinitely until the channel is selected. after a channel is selected the set will run fine the rest of the day. the unit has high voltage, filaments, & vertical sweep during the no raster condition. After first turning on the set the cathodes of the crt are measured with an oscilloscope. an interesting fact that after the set is turned on tsound are no visible ik pulses on any of the crt cathodes. ik pulses only appear when the channel is addressed with the remote or the channel up down command on the television. initialization of the eeprom did not correct the symptom. no incorrect values found in the alignment parameters. only by elimination was the trouble found to be in the eeprom. Muller
SONY KV27V25
AA-2
System control Unit has intermittent snow in the picture. 8-598340-20 tuner was replaced. now the set has a symptom wsound the remote control causes the set to enter the video input mode when the channel is selected. also the set will enter the video input mode if another brand of remote that operates a stereo receiver is used. I instructed the tech to enter the tech mode and set the id codes...id0=25, id1=23, id2=47, id3=0, id4=27,id5=135, id6=1, id7=0 . write these in memory, then press ""8"" ""enter"" to initialize. "" Muller
SONY KV27V22
AA-2
System control Kv27v25 unit has intermittent snow in the picture zthe tuner pn# 8-598-340-20 was replaced. now the set has a symptom wsound the remote control causes the set to enter the video input mode when the channel is selected. also the set will enter the video input mode if the and another brand of remote that operates a stereo receiver will put the set into the video input mode. I instructed the tech to enter the tech mode and set the id codes...id0=25, id1=23, id2=47, id3=0, id4=27,id5=135, id6=1, id7=0 . write these in memory, then press ""8"" ""enter"" to initialize. this corrected the problem. "" Muller
SONY KV27FV15
AA-2
System control Kv27f15 the set has a symptom of the keyboard doing the wrong functions. cannot get into the tech menu. when the display button is pushed the set will shut off. Checking key-in to the i001 we found it to be sitting at 3.7 volts without any keys pushed. this is an analogue input to the cpu and must be at 5 volts with no keys pushed. keyboard had small board contamination on the channel down switch. removing the channel down switch corrected the problem. all remote control functions return to normal and so did the keyboard functions Muller
SONY KV27S40
AA-2
Squeal Kv35s40unit is making a noise internal to the television that resembles the sound a fax machine makes when listening to it over a telephone connections These sounds are apparently caused by loose laminations in the linearity transformer. it is suggested the tech replace l511=1-406-607-41, c520= 1-101-821-00(.002 mfd @ 500 vdc) r506 =1-215-861-00(47Ω@ 1 watt metal film) Muller
SONY KV27V22
AA-2
Shutsdown Kv27v22 serial 8004933 unit has a green screen with slight retrace lines, tapping on the neck of the tube aggravates the green drive then the set shuts off. Crt.. due to this trouble i suggest that we replace the crt a68kzj50x Muller
SONY KV32XBR48
AA-2
Shuts down Kv32xbr48 unit get a bright red screen then looses horizontal sweep then shuts down. unit can be turned on again right away Tech needs to tap on neck of crt and see if the symptom is aggravated by this action. after tech got to the house an tapped on crt it was founf that the tube was causing the Muller
SONY KV35V35
AA-2
Shutdown Kv35v35 serial 9011978 unit flashes bright green with retrace lines then shuts down. when powered back up sometimes the set will be in the ""video 1"" mode. "" ?unit has a defective crt. a89ljt80x Muller
SONY KV32S65
AA-2
Shutdown Kv32s65 unit goes into shut down. will allow hv to com up but goes into immediate shut down afterwards. at no time did we ever have data on 9 & 10 of the jungle ic Open coil that supplied the b+ to the audio controller and bμFfer chips. this loss in voltage caused the audio processor chip to load down the data and clock lines and cause this symptom. Muller
SONY KV32S40
AA-2
Shutdown Kv32s40 unit will turn on and immediately shut down. it does get high voltage briefly. appears to be entering over current shutdown. waveform at the collector of the horizontal output appears normal. horizontal drive is normal if the horizontal output transistor is removed. Severing the 135 b+ line and placing a 40 watt bulb in series with the supply were are still getting the same symptom but the light illuminates brightly. we began to disconnect the flyback loads d530, d531. after disconnecting these we found the set will run with d530 disconnected . checking this device it passes the static check. this component is the -15 volt power supply. it was suggested to replace d530. this corrected Muller
SONY KV32S22
AA-2
Shutdown Kv32s22 serial # 8055057. unit will run fine for 15 ~ 30 minutes with sporadic arcing then it will shut down with a bright green flash Unit needs replacement crt 8-733-741-05. Muller
SONY KV24FV10
AA-2
Shutdown Kv24fv10 unit will shut down immediately after turn on. but the unit will stay on if the service mode is entered.. When monitoring the vp at ic001(18) only 1 volt peak to peak was measured. floating ic001(18) allowed the voltage to return to 5 volt pp. replacing the ic001 corrected the Muller
SONY KV35V36
AA-2
Shut down Kv35v36 serial 9024090 unit has an intermittent shut down that only occurs after two or three days. when shut down occurs, the led in front is blinking and raster disappears but sound is ok. when flexing, heating, or freezing the main circuit board the problem can never be recreated. Tech needs to order the crt. since we are not able to confirm any trouble with chassis the crt is nearly out of warranty. it is recommended that since we are unable to determine any chassis fault the problem must be due to crt arc over. note after 4 weeks of normal operation the crt seems to have corrected the symptom. Muller
SONY KV32S65
AA-2
Shut down Kv32s65 intermittently the set will turn off. this process takes about 30 ~ 60 minutes. the set can be turned back on again if the power button is pressed twice. sometimes the set comes on in the video 1 input mode when it was in the tuner mode before it shut down. This could be caused by the crt. suggest the tech disconnect the crt socket an run the set with the tube disconnected and see if the set shuts down with the crt disconnected. with the tube disconnected the chassis ran 3 days without shutting down. a crt was substituted and the problem never showed up on the other crt. replaced the crt and it corrected the symptom. Muller
SONY KV32S25
AA-2
Shut down Kv32s25 unit will not develop high voltage. when the set is turned on no high voltage appears. the set has sound and has a flashing light on the front indicating the set is still in a stand by mode waiting for ik pulse feed back acknowledgement from the jungle ic When monitoring the horizontal output collector we found the 140 dropped slightly at turn on. but the horizontal driver q501(c) dropped to 85 and back up to 140. i had the tech to remove the horizontal output transistor and try starting up the set again. after power up measure the q501(c) horizontal driver transistor. it should be about 85 volts and stayed. this told us we were looking at a shutdown symptom. checking all secondaries we found nothing shorted. replaced flyback which corrected trouble. Muller
SONY KV32S40
AA-2
Shading Kv32s40 brightness shading in brighter on the right side than it is on the left side of the screen. symptom only shows up in the tuner mode. vcr in video input mode is fine. unit has catv box ""scientific atlantic model 8580338"". "" After checking out the box and moving the box it was discovered the movement of the box effected the screen brightness. the box was mounted directly beneath the television. if the box was moved to the far left the symptom disappeared. if centered below the tv the symptom was evident. solution was to move the catv box away from the television and remove any electromagnetic interference caused by the television. Muller
SONY KV27V40
AA-2
Retrace lines Sony kv27v20 has retrace lines no video. unit will shut down if left on after the filaments warm up. Missing 200 volt power supply from flyback to crt driver board. trace broken at cn1781 Muller
SONY KV27S25
AA-2
Retrace lines Sony kv27s25 bright screen with retrace then unit shuts down I had tech measure the 200vdc supply line and it measured only 78 volts. unit had defective capacitor in the 200 vdc power supply. Muller