Sony Repair Tips
Search: sony
Results: 20100
Results: 20100
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
KV35V35
AA-2 |
Horizontal sweep | Kv35v36 product has a insufficient horizontal sweep. the sweep is reduced by 10 to 15% on the left side and 2 ~ 5% on the right. | When going into the tech set up parameters and adjusting the hsiz value the sweep will replace to full sweep. monitoring the voltage at the collector of @q512 the voltage will vary from 27 volts hsiz set to 22. when hsiz is set to 48 q512(c) will drop to 16 volts. the set will have full sweep but it has a slight foldover condition on the right side of picture. it is recommended the tech replace the retrace capacitors c511, & c513 and the yokes"" capacitors c518, & c515. tech replaced all of the capacitors and the symptom "" | Muller |
SONY |
KV32S40
AA-2 |
Horizontal sweep | Kv32s40 ser 8053998 unit has sever over scan of horizontal sweep. tech replaced q512 shorted and q511 open all elements. | Measuring the collector of q512 tech finds the voltage running in excess of -7 volts. the voltage on this transistor in inconsistent with the symptom on the screen of a narrow raster that is hourglass shaped. l511 and q512 are burning up. suggest the tech replace the following additional components d502, d503, d504, c511, and c513. | Muller |
SONY |
KV27S20
AA-2 |
Horizontal lines | Sony kv27s20. black banding across the screen. symptom does not appear when playing a tape. | Gave tech modification on the kv27s20 to replace c1267 from a .047 to a .47 tantalum capacitor. | Muller |
SONY |
KV32S40
AA-2 |
Horizontal | Unit has severe over scan of horizontal sweep. tech replaced q512 shorted and q511 open all elements. | Measuring the collector of q512 tech finds the voltage running in excess of -7 volts. the voltage on this transistor in inconsistent with the symptom on the screen of a narrow raster that is hourglass shaped. l511 and q512 are burning up. suggest the tech replace the following additional components d502, d503, d504, c511, and c513. | Muller |
SONY |
KV36FV1
AA-2 |
Horizontal | Unit has a severe over scan condition for horizontal sweep. tech did not measure any voltages in the pin amp circuit. | Tech needs to check on l511, q512, c513, c511, d502 & d504. one or more of these are shorted. | Muller |
SONY |
KV35V36
AA-2 |
Horizontal | Unit has a insufficient horizontal sweep. the sweep is reduced by 10 to 15% on the left side and 2 ~ 5% on the right. | When going into the tech set up parameters and adjusting the hsiz value the sweep will replace to full sweep. monitoring the voltage at the collector of @q512 the voltage will vary from 27 volts hsiz set to 22. when hsiz is set to 48 q512(c) will drop to 16 volts. the set will have full sweep but it has a slight foldover condition on the right side of picture. it is recommended the tech replace the retrace capacitors c511, & c513 and the yokes"" capacitors c518, & "" | Muller |
SONY |
KV27S25
AA-2 |
High voltage | Unit has no high voltage. led in front is flashing on and off after power up. | Tsound does not seem to be any horizontal drive to the horizontal drive transistor. defeating the horizontal output by removing the collector connection still will not allow horizontal drive to appear at ic351(37). this pin is sitting at nearly 8.5 volts, not the 3 volts it is supposed to be. also ic351(38) the hoff/afcpin is at 3.3 volts which is normal. unit has a bad ic351 cxa2025as | Muller |
SONY |
KV36FV1
AA-2 |
Geometry | Kv36fv1 serial 9032273 tech needs yoke modification for the yoke upgrade. | Gave tech bulletin 387r2 relating to the shoulder roll off | Muller |
SONY |
KV32S45
AA-2 |
Geometry | Kv32s45 serial 8102913 picture is rotated clockwise by 1/4 inch. tech claims this tube does not have a pix tilt circuit or rotation on the crt bell | Tech needs to break the bonding of the yoke ant reposition the yoke. | Muller |
SONY |
KV27V65
AA-2 |
Geometry | Kv27v65 serial 8027393 customer complaint is a slight geometry error or tilt in the lower right hand corner of the screen. it causes a symptom of horizontal lines that are not perfectly straight. in this case the lines are elevated by at width of 2 horizontal lines. | This television is operating within specifications. the geometry errors should not deviate more than 1/8 of an inch across the length of the horizontal line. horizontal tilt can be no more than 1/8 of an inch. this television beats this measurements. tsound is nothing i can recommend to the tech to do to improve on the geometry of this receiver. | Muller |
SONY |
KV27S10
AA-2 |
Geometry | Kv27s10 serial 723009 unit has symptom every time the set looses power the geometry memory is lost vpos, vsiz, hsiz. pamp drop at least 10 points each. when resetting these values and writing them to memory the they will be erased as soon as power is removed | Tech needs to replace the eprom??. i002 corrected the problem | Muller |
SONY |
KV36FV1
AA-2 |
Focus | Kv36fv1 serial 9046442 unit has poor focus on left and right side of picture | The set has a dynamic focus error. tech needs to see if the dynamic focus circuitry is running correctly. also before any hardware is tested the parameters of hamp and dcsf should be adjusted to see if the dynamic focus is effected. when adjusting these parameters the values get the best focus when each is mixed out to 60. the focus becomes poor 2 inches from the left side of the screen and 5 inches from the right side of the screen. | Muller |
SONY |
KV36FV1
AA-2 |
Focus | Kv36fv1 customer is running the television on a dss satellite system. customer claims the set looses focus in the picture when tsound is a lot of detailed movement. | This is caused by the 10 megabit throughput limit of the dss video compression format mpeg3. in order for the compression to work correctly the digitization process only updates the data that is changing. background data is not updated as regularly as the foreground data. hence when everything must get updated. but the max data throughput is finite. the entire video waveform will not be accurately represented, instead the smaller detailed portions of the picture will begin to have larger pixels so not to exceed the max data. this is why to the eye the set appears to loose resolution or picture detail. this is normal. | Muller |
SONY |
KV36FV1
AA-2 |
Dead | Unit is dead. after talking to customer they explained that they had a power surge caused by a car hitting a power pole. | The set was completely dead. vdr602 was noticeably burned up. cutting this device our of the circuit found that it was open. however the device is connected in the circuit like a metal oxide varistor. it should measure open since it is in parallel with the a.c. line. it was discovered that no other shorted components could be found in the primer of the power supply. main line fuse was not blown! checking the raw ac voltage on the ac line filters t601, and t602 find that we have no ac voltage on the output of t602 but present on the input side. isolating the open coil and removing the defective vdr602 allows the set to turn on and operate correctly. tech will need to replace t602 and | Muller |
SONY |
KV27V65
AA-2 |
Dead | Unit is dead tech replaced the ic601 and r607 and the flyback, but when power was reapplied the set destroyed the power supply again. | Unit had a blown ic601 and r607. tech had failed to check the condition of the power supply output for the 135 vdc power supply.. it was discovered tsound was a 1.2Ω short to ground caused by a shorted protect diode in the secondary of the power supply. i cannot stress enough the tech needs to check all loads on the secondary of the power supply for shorts, and use a variac to start up all power supplies. all parts replaced earlier are destroyed and need to be replaced | Muller |
SONY |
KV32XBR48
AA-2 |
Dead | Originally dead with shorted ic601 converter ic and horizontal output transistor shorted too. | Checking the collector of the horizontal output transistor the retrace period was running in excess of 20 microseconds not the traditional 11.5 microseconds. closer inspection found the deflection yoke leads inside the connector were loose and the crimp for the wire to the horizontal winding were not making contact to the terminal inside the connector. | Muller |
SONY |
KV36FV1
AA-2 |
Dead | Kv36fv1 serial 9029271. unit is dead. after talking to customer they explained that they had a power surge caused by a car hitting a power pole. | The set was completely dead. vdr602 was noticeably burned up. cutting this device our of the circuit found that it was open. however the device is connected in the circuit like a metal oxide varistor. it should measure open since it is in parallel with the a.c. line. it was discovered that no other shorted components could be found in the primer of the power supply. main line fuse was not blown! checking the raw ac voltage on the ac line filters t601, and t602 find that we have no ac voltage on the output of t602 but present on the input side. isolating the open coil and removing the defective vdr602 allows the set to turn on and operate correctly. tech will need to replace t602 and | Muller |
SONY |
KV35S26
AA-2 |
Dead | Kv35s36 serial 9027801 unit goes dead after 10 minutes after the power supply was repaired.q601 & q602 were not running hot they just shorted. they were replace 4 times. each time the transistors lasted 10 minutes and in 1 case 1 week. | After running the television for over 1 hour with the crt disconnected it was determined the power supply, deflection, and horizontal deflection were all working. it was further decided to replace the crt needs to be replaced. crt fixed the unit. | Muller |
SONY |
KV32XBR48
AA-2 |
Dead | Kv32xbr48. originally dead with shorted ic601 converter ic and horizontal output transistor shorted too. the horizontal drive looked odd, but this was not the problem. | Checking the collector of the horizontal output transistor the retrace period was running in excess of 20 microseconds not the traditional 11.5 microseconds. closed inspection was found the deflection yoke leads inside the connector were loose and the crimp for the wire to the horizontal winding were not making contact to the terminal inside the connector. cleaning the terminal and prepping the connection was necessary because tsound was evidence they were burned by the voltage drop in the poor connection . | Muller |
SONY |
KV32V40
AA-2 |
Dead | Kv32v40 unit was originally dead. q502 was replaced. now set has a sever over scan of horizontal sweep. collector of q512 only 2 volts q512 was shorted. l511 is burned and needs to be changed, along with d504 d503, d502, c511, c513, and l511. | After replacement of the components the sweep was still excessive. when using an oscilloscope on the ic351(31) the e/w pin out we found 6 volts dc, and no 60 hz parabolic wave form. if this e/w output pint was touched to ground through a 270Ω resistor the picture narrowed up to a an almost normal width. product had defective ic351. | Muller |