Sony Repair Tips
Search: sony
Results: 20100
Results: 20100
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
DTC670
|
Distorted audio - drum assy faulty, p/n 8-848-567-11 | The unit had either no audio or distorted audio on playback ofthe self-recorded and pre-recorded tapes. | ||
SONY |
SLV750HF
|
No picture in pb: resolder pins of ic203 ma144 board | There was either no picture, or bad picture in playback. | ||
SONY |
MDP605
|
Play intermittently but no pause mode: f102 sv-60 | If the pause button is pushed while playing a side cav disc,the picture goes backwards. the picture goes forward while playing b sideclv disc. also, there was no cd play at all. | ||
SONY |
WMSXF33
|
Low volume/ mega bass does not work - resolder q-303 | The unit had low volume (the maximum volume was not right).also, the mega bass switch would not work (there was no mega bass). ifound a cracked solder connection on c203 and then found no vcc to ic302(bass boost ic). i followed it to q303 on the main b | ||
SONY |
CFSD960
|
Replacement head has extra wire - jumper yellow and brown | Original head had six wires. | ||
SONY |
CPD1430
|
Blue color missing | Missing blue. | ||
SONY |
CPD1430
|
Bright red retrace lines | Overdriven red raster with retrace lines caused by shortedq504. -hq comments: also see fpr # o1332 | ||
SONY |
KV2084R
|
Bright scenes overdriven, l922 open | Certain bright scenes appear overdriven. l922 proved to beopen which altered the bias voltage to the video buffer q935. -hq comments: with l922, the video dc level is shifted. | ||
SONY |
CDPC1750
|
Drawer won't stay open (dislodged cushion interfered w/s103) | S103 (tray out) was not being closed. there was a cushionpreventing the tray from sliding all the way out. | ||
SONY |
CDP397
|
Wrong part number for m102 (correct # is x-4917-523-3) | The correct part number for spindle motor m102 isx-4917-523-3. the sled motor is part number x-4917-504-1, this is themotor without a reference number. | ||
SONY |
CDPH1750
|
Does not read or spin disc (replace ic209, p/n 8-752-352-93) | There was no focus search, no laser, no spindle action. theunit does not spin the disc. | ||
SONY |
XRU660
|
Unit inoperative (replace r569, 2.2 k, p/n 1-216-057-00) | The unit did not have any power, it was inoperative. | ||
SONY |
CDP470
|
Disc drawer does not open (only when using thick discs) | The cd is stuck inside in the unit. the disc drawer won'topen. this problem only happens with some thick cds. the spindle motorheight was within specification. | ||
SONY |
EXCD40
|
Slow eject cycle (replace sw80, sw81, p/n 1-571-754-11) | The tuner operation was normal. when ejecting the cd, the mechanism will move to the lock position, but the solenoid plunger 332 will take thirty to forty seconds to engage to finish the eject cycle. | ||
SONY |
XK8D
|
Part # correction q-652, supp. 1 (order p/n 8-729-140-75) | The part number for q652 is incorrect as listed insupplement 1. it lists q652 as 8-729-188-23 which is a 2sd882. | ||
SONY |
TAE511
|
Unit inoperative - ic101 faulty, p/n 8-759-154-42 | The unit would not power up at all. the display control boardwas getting power but ic101 was not responding. | ||
SONY |
TAAV421
|
Unit inoperative - ic101 faulty, 8-759-062-41 | The amp would not come on at all. | ||
SONY |
STRGX67ES
|
No audio on channel "a" front speakers - ry703 1-515-741-21 | The unit did not have audio out of the a speakerterminals. the b speakers and headphones were ok. | ||
SONY |
TAAV421
|
Inoperative except for light on volume control - cj103 | The unit was inoperative, only the red light on the the volumecontrol was lit. | ||
SONY |
STRAV770X
|
Unit inoperative - q812 faulty, 8-729-119-79 | The unit was inoperative, it would not come on at all. |