SONY FDL310
Tu board different than found in the s/m, correction issued Tu board is different from the one in the service manual.also q-402 is a smaller type with x7 stamped on it. need the correctschematic and part number for q-402. -hq comments: q-402 was changed to 2sd1048x7 its part number is8-729-800-78, which as be
SONY XRU330
Unable to correctly insert front panel section Unable to correctly insert front panel section as per manual.
SONY SPPA60
Part number availability for battery sponge In the service manual there is no part number supplied for thebattery sponge that is attached to the handset rear cover.
SONY SPPA40
Part number availability for battery sponge In the service manual there is no part number supplied for thebattery sponge that is attached to the handset rear cover.
SONY CDPC225
Intermittently will not turn on Unit intermittently will not power up.
SONY KP5040
Inoperative set - no relay click, replaced q-654 (ga board) Inoperative set with no relay click. found no +12v dc at plugga-13 pin no. 3. found q-654 open emitter to base.
SONY CCDV5000
New audio/pcm pc board version incompatibility/sm supp-1 Instead of pc-35, we found a different version pc-52, withcustomer complaint as huming noise as in manual mode, even with and levelcontrol at minimum setting (0) level. the circuit is different withpc-35. replaced with pc-35 that solved the hum. all a
SONY HCDH50
Unit stuck on 9khz spacing Unit is stuck on 9 khz spacing on a.m. how do you change from9 khz to 10 khz spacing?
SONY HCDH1600
Substitute ic-205 requires circuit changes - d-101 fails Kcp automatically subs this chip to a cxa1492aq, part number8-759-058-95. when you install the new device, d-201 fails and the newchip may fail also.
SONY FDL3500
Max and mim current, 2-3 ma mim, 500ma max Customer complaining about short battery life. the servicemanual does not supply the minimum current drain when the set is in theoff position. can you supply? -hq comments:tv mode: 500maam/fm mode: 60maoff: 2-3ma
SONY MZ1
Restoring unusable m/o discs to usable condition The display shows utoc error when trying to read an m/odisc. this problem may have been caused by the customer moving the unitwhile it was updating the utoc area after recording. the owner's manualindicates that the disc must be replaced.
SONY CCDTR5
Service bulletin number cam0171 - original screws too short When performing service bulletin no. cam0171, and installingthe new base block assembly the original mounting screws are now tooshort.
SONY XRU770
Amp remote stays on with power off Customer states that power amp stays on even when unit is off.
SONY CCDTR81
Intermittent play - shutdown in rewind/relay belt ref 367 Unit would play for a short time and shutdown. shutdown inrewind occasionally eats tapes.
SONY CCDTR1000
Owner's manual for ccd-tr1000/same as ccd-tr101
SONY CCDTR101
Unit will not edit search/defective switch block Edit + and - both would cause tape to roll. however, videowould be muted. suspect faulty matrix.
SONY CCDV801
Circuit boards are different/sm supp-2
SONY HSTV102
Need motor mount part number Part number for motor mount shown on page 28, shown as notsupplied. part got thrown out with old motor. -hq comments: we have contacted tokyo and they have agreed to send onepiece for the repair of this unit. we will inform you once we receive it.4/22
SONY KV32XBR15
Bad pincushion, q-505 gets hot, replaced l501 Servicer had problem with pincushion. replaced r-571, q-505and d-512. checked l-501 and thought it was ok. it read about 2Ω andit should be approximately 4.5Ω. i suggest a service bulletin beissued concerning the above. -hq comments: please
SONY PVM1271Q
Picture had severe pincushion Monitor had a severe pincushion problem and was expandedhorizontally. pin and horizontal controls had no effect. traced problemto pincushion transistor q-806. voltage at the collector of q806 was 3.4volts, not 35.1 volts as stated in the service manua