Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
ITA555
|
Ic-602 on back order at kcp. | Asc reported three units with a bad ic-602. also applies toserial number 101395. -hq comments: we checked with kcp. the parts are on back order. theestimated time of arrival is april 15, 1993. | ||
SONY |
ITA505
|
Ic-602 on back order at kcp, | Asc reported three units with a bad ic-602. also applies toserial numbers 120679 and 120596. as of today there are 216 on back orderat npc. -hq comments: we checked with kcp. the estimated time of arrival of theparts is april 15, 1993. | ||
SONY |
KV32XBR95S
|
Inoperative set, replaced ic-1401 | Relay would not click when power button is pushed. it wouldclick when unit is plugged into ac. unplugged connector g-5 on g boardand power switch would work. | ||
SONY |
KV27XBR95S
|
Inoperative set, replaced ic-1401 | Relay would not click when power button is pushed. it wouldclick when unit is plugged into ac. unplugged connector g-5 on g boardand power switch would work. | ||
SONY |
CCDTR51
|
No camera picture after warm up | After warm up, camera picture fades out to black with streaksfrom left to right. the vcr playback is ok. | ||
SONY |
STRGX99ES
|
Unit intermittently in protect mode, bad solder on "a" board | Unit would intermittently go into protect mode. found thatmoving class a pcb would cause this to happen. second unit withproblem. | ||
SONY |
SLV585HF
|
No drum rotation | Drum would not spin. drum acted as though it had a flat spot. ie: if rotated a few degrees or spun while loading unit would work ok for an instant. | ||
SONY |
CCDF31
|
Broken connector | No zoom control. found break in ribbon connector at pointconnector is inserted. by the looks of the design this might be aproblem. the connector is looped on the cassette compartment and isextended on elect and flexed when its loaded (g. sperakos). | ||
SONY |
KV19TS20
|
Shutdown when picture or brightness levels increased, r-568 | When either the picture level or the brightness level wasincreased, unit would go into hv shutdown. found that with picture andbrightness levels low, q-552/base was at 0.4vdc, and q-552 would turn onas levels increased, causing q-552/collector and ic-30 | ||
SONY |
CCDTR71
|
Audio volume up and down constantly on left channel | Playback audio is distorted , the volume level goes up anddown constantly on l-channel. muting detection circuit capacitor/c-618found to be cracked on au-135 board. | ||
SONY |
SLV585HF
|
Intermittent power | Intermittent power and display. | ||
SONY |
SLV696HF
|
Will not power on | Wouldn't power on. | ||
SONY |
SLV595HF
|
Won't load tape | Wouldn't load tape. | ||
SONY |
ITA850
|
Ogm tape jamming | Ogm tape jamming. | ||
SONY |
DTC700
|
Dropouts on record/playback - incorrect tape path and dpg | When recording, music would drop out, and also playback wouldhave dropouts. | ||
SONY |
SLV595HF
|
Unstable picture and audio. | Picture and audio unstable. counter problems also. | ||
SONY |
SPP65
|
Won't get line | Handset won't ring or get dial tone. | ||
SONY |
D808K
|
Cd won't play - replace spindle motor, p/n x-262-528-91 | Cd won't play. | ||
SONY |
CDPC221
|
Cd only plays first 40 seconds, then repeats | Cd would read toc and play the first 40 seconds, then repeatitself. | ||
SONY |
CCDV101
|
No cassette load - eject was normal | During cassette load, the drum would start but unit would notload and capstan would not turn. using the cassette with the mode box, theunit would eject fine (load motor, capstan and drum would all run). whentrying to load a tape while drum was running, t |