Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
STRGX40ES
|
Pop noise in audio when tape mon pushed | When connecting a tape deck to monitor inputs/outputs, theoutput to the deck is muted momentarily when the tape monitor switch ispressed on the front panel. this should not happen. as the purpose ofthe monitor circuit is to allow the user to check a re | ||
SONY |
KV27HSR10
|
No part number cp-111, 1-232-680-11 | Part number for the cp-111 pack is missing from the manual. | ||
SONY |
CDPC10
|
The unit locks up after playing a disc, ic-209 defective | After unit finishes disc, it locks up, and only turning itoff and on again will restore manual play. following the chart from themanual i figured out that motor m-3 fails to work intermittently when itwas supposed to position the played disc in front of | ||
SONY |
TCH3600
|
Service manual errors - display circuitry | From page 21 of the service manual, ic-351/pin 12 shows-4.7vdc. should be the same as pin 26, +5.4vdc. also connectorcn-351/pins 1 and 2 show ac to the display filaments. from page 20,q-619 and q-620 and t-601 etc. oscillate at approximately 40khz, re | ||
SONY |
MZ2P
|
Does not work with ac adaptor (fusible link ps-401 open) | The unit does not operate when powered by the ac adaptor only.the unit works fine if the battery pack is installed and is chargedsufficiently, but the battery pack is not charging when the ac adaptor isplugged in. | ||
SONY |
CDPH3750
|
Does not read discs | Unit spins disc and servos appear to be working but displayreads no disc. found small holes in traces. | ||
SONY |
GDM2036S
|
No vertical deflection | Unit has no vertical deflection. checked and found openvertical yoke. tried to locate the open, and found c01 on the yoke ass'yopen. the coil is made up of large wire, so it cannot be defective. | ||
SONY |
GDM1936
|
No vertical deflection | Unit has no vertical deflection. checked and found openvertical yoke. tried to locate the open, and found c01 on the yoke ass'yopen. the coil is made up of large wire, so it cannot be defective. | ||
SONY |
CDX5040
|
Doesn't read toc | Unit would load disc, spin but not read toc. observed thatlaser was not coming on but focus search was. tried new fop and rf amp,but they did not solve problem. | ||
SONY |
EXCD40
|
Preventing damage to "e" flexible board | The flexible board which runs from the main board to the frontpanel board rubs on the retaining tab protion of the frame until theprotective coating is worn through. this allows the printed traces of theflexible board to ground against the frame, thus c | ||
SONY |
SPP160
|
Unit inoperative while talking | Unit becomes inoperative while talking. | ||
SONY |
SPP115
|
Not charging - reposition battery contacts | Base would not charge batteries. | ||
SONY |
SLV393
|
After warming up drum speed up | When playing a tape for about 1/2 hour, the drum speed wouldspeed up and the unit would shutdown. | ||
SONY |
SPP170
|
Static heard in unit. | Static heard in unit. found broken trace on dpx-1. | ||
SONY |
ITA205
|
No tape motion | Tape would not play. | ||
SONY |
SLV696HF
|
Won't playback ep when the "ma-106" is replaced | I replaced the ma-106 board and the unit would not pb eprecordings. | ||
SONY |
SLV555UC
|
No power | Unit would not power up. | ||
SONY |
SPP110
|
No power | Handset had no power. | ||
SONY |
SLV585HF
|
Right audio channel out | No right channel audio. | ||
SONY |
SPP320
|
Very staticy/no distance | Very staticy with no distance. |