Make Model Symptom Problem Solution By
SONY CCDF56
Not sharp view or focus Chroma only, little or no luminance, playback normal. cameray appeared normal entering ic-401, but no output. determined ic-401 isdefective.
SONY CCDF401
No image in viewfinder Camera picture is normal, distorted viewfinder raster on videoand found incorrect drive frequencies which indicated a defective ic-901.
SONY CCDF301
No picture in viewfinder Viewfinder picture initially is normal. abruptly changed toexcessive brightness with complete loss of video. found apparent internalheater cathode short in crt.
SONY SLV353UC
Shuts down in play and won't accept tape Unit would shut down, traced problem to defective cam gear.
SONY TCDD3
Tcd-d3 mechanical alignment
SONY TCDD3
Tcd-d3 mechanical alignment Unit shows caution on the display. we have followed stepsnos. 1-6 according to s/b hfp0203 with negative results. when power isapplied to the unit, press power and cassette compartment ejects by itselfwithout pressing the eject button. when press down
SONY D303
How to connect lcd flex cable to keyswitch flex board How can we connect the flex cable of the lcd to the keyswitchflex board? they appear to be bonded together by a means other thansoldering. we have a customer's unit which cannot be repaired because wedo not have any information on this type of connecti
SONY CPD1304
Intermittent failure of q-401 I've heard reports that intermittent failures of q-401 can becaused by leaky diodes d403-871911013 and d404-871930186.
SONY SLV575UC
Test tape krv-51n part number What is the part number of the krv51n vhs test tape referredto in fpr m1289?
SONY SPTC200
No video No video output. traced problem to r-333 and one end hadvideo the other end did not.
SONY TADM1000ES
Unit goes into error Unit would power up, receive switching signal and go intoerror.
SONY D66
No left channel audio on headphones No left channel on headphones. third unit with this problem.
SONY D9
No play (no spindle drive, no focus search, no sled drive) Unit's display came on but did not focus search. neitheric-502 nor ic-601 had power. found q-407 to be open. i have seen threeunits with this symptom.
SONY D11
No line out audio No line out audio, right and left channels of hp jack seem tobe ok.
SONY D4
No power - intermittent When play was selected, the display would light up for a sec-ond and fade fast. found that l-401 was open.
SONY KPR46EX25
Replay title locks on, ic-1202 also check d-202 Unit will display large replay title in green at center ofscreen. is activated by ch index. when it happens, volume level bar andpicture level bar do not display at bottom of screen. replay cannot beeliminated and set must be unplugged or microprocess
SONY D180K
No play Unit would not play discs. in the test mode no searchfunction occured. there was a reading of 1 volt (b+) on pin no. 38(ic-504).
SONY EDV9500
White drop outs at top of screen (approximately 2 inches) Unit had white drop outs in top of picture (approximately twoinches in size.
SONY STRGX57ES
Unit goes into protection with high volume on rear amp. Setting the rear amp volume to high causes the protectioncircuit to activate. i connected 8Ω dummy loads to the rear output andthe output clips unsymmetrically with a birdie on the positive half-cyclebefore the bottom half-cycle shows any distortion.
SONY SLHFR70
Eratic operations - intermittent Intermittently all or incorrect portions of lcd would lightup. basket would load but not thread with or without tape inserted.continuous reel motor rotation. after five seconds, basket would unloadreel (motor still running) five seconds later basket wo