Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
ICF7601
|
No audio upon power-up | Unit powers up - no audio. | ||
SONY |
D25
|
Disc does not spin | Disc does not spin. open line between ic-502 pin 39 - spindleoutput and ic-504 pin 37. | ||
SONY |
D66
|
Dead unit | Dead unit 3.5 volts b+ for micro ic-801 missing. c-424shorted. | ||
SONY |
SLV373UC
|
Blue screen in loop thru e-e | When playing back a copy-guarded tape on another machine whoseoutput is looped through the 373uc, then on to the monitor, anintermittent blue screen occurs. -hq comments: this is normal. in this unit the input signal is routedthrough the record circuit | ||
SONY |
D7
|
Audio output | This unit had no audio out. c-407 was shorted blocking the-4.7v supply to the d to a converter. | ||
SONY |
WMF2078
|
Service manual has belt diagram in wrong position | On page 21 of the service manual, the belt diagram whichindicates belt routing is incorrect. | ||
SONY |
WMF2081
|
Lcd display is out if batteries are removed | No lcd display while batteries are removed.power up unit with 3v adaptor, lcd display is back. remove 3vadaptor and display stays on. cannot find backup power for display. -hq comments: there is no backup battery in this unit. however, c-921(0.06f) w | ||
SONY |
SLV555UC
|
Will not load some brands of tape | When attempting to load certain non-sony video tapes (espec-ially rental tapes), the machine would not accept them. these tapes workin other models/brands. the tape submitted by the customer doesn't havethe release button extend out of the case to the | ||
SONY |
KV27XBR10
|
No audio | Audio is stuck on sap mode only. there is no audio on mainor both modes. | ||
SONY |
SPP320
|
Static in receiver (both parties) | Excessive noise added to phone line through mic 101 whentouching handset (cordless) case. even handset rubbing against the facecauses noise. all spp-320s handsets appear to have this problem. | ||
SONY |
CCDF70
|
Dd motor noise recorded | Dd motor noise is recorded in audio. i changed the dd motorand customer is still not happy. | ||
SONY |
CCDTR6
|
Stuck iris | Iris sticks, no camera video. disassembled lens and found oilon the iris petals. | ||
SONY |
KV27XBR10
|
Set goes into ovp intermittently at turn on, replaced q-651 | Set goes into ovp intermittently at turn on (every 4 out of 5times). when unit works, all voltages are correct. | ||
SONY |
DT2
|
Upper volume distortion and low midrange audio | Distortion was detected when the volume was increased to theupper and even more noticeable throughout the full volume range was thelow midrange. audio was missing the expected fullness. line-out playedfine as with all other functions and waveforms. | ||
SONY |
D2
|
Laser light always on (intermittent play) | Laser light was always on even when the lid was open. whenplay was pressed, a lot of noise in the motor was heard but played inter-mittently. another noticeable symptom was the lcd showed all of it'scharacters as if it were getting too much voltage. | ||
SONY |
MDP700
|
Disc is intermittently ejected | Cd or lp intermittently ejects during or before play. | ||
SONY |
SPP120
|
Part number clarification - ref #52 buttons | Pictorial on page 42 gives the impression that if you orderno. 52 you get all four buttons but you only get one. | ||
SONY |
SPP170
|
Part number clarification - ref #52 buttons | Pictorial on page 42 gives the impression that if you orderno. 52 you get all four buttons but you only get one. | ||
SONY |
SLHF860D
|
Part number for record button | A servicer here requires the record button for the abovemodel, but when he orders ref. n0. 7 in the attached diagram, he onlyreceives the cover by itself. he needs a part number for the actualrecord slide button by itself. can you please help? -hq com | ||
SONY |
D99
|
Disc spins backward | When disc is inserted and play button is pressed, disc startsto spin, stops and spins backward (counter clockwise). -hq comments: the unit is a prototype with no model number, or serialnumber. this unit internally was very similar to a d-99. using the |