Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
PVM2530
|
Horizontal line on center screen | Screen appears completely black with the exception of a horizontal line across the center of the screen. | ||
SONY |
TCWR9ES
|
Quick auto reverse | Unit will not quick auto reverse on both decks as advertisedin the attached brochure. according to service manual, only b deck hasthe circuit for quick auto reverse as shown on the schematic attached. -hq comments: thanks for the info. you are right, a | ||
SONY |
CCDV9
|
Color distorted and flashing | Color distorted in play, ok in pause. sometimes colordistorted in pause, ok in play. | ||
SONY |
CCDV11
|
Dew sensor on | Dew sensor on. | ||
SONY |
CCDF40
|
Poor playback | Playback picture on tv monitor displayed bad heads, but rfenvelope looked good. traced signal to soft limiter circuit where rfentered but left distorted q-376, 378 and 379 had no 5v supply. | ||
SONY |
MDP210
|
No video or rf | Unit read disc and had audio but no video or rf. found videoat pin 13 of ic-103 but not at pin 13 of ic-602, nor at q-610. | ||
SONY |
WMA39
|
Wrong part number listed in manual | Part number for reference number 904 is listed as1-623-643-11. this is wrong (page 12 of manual). | ||
SONY |
SPPS10
|
Test connector for alignment of rf section. | How do you align rf section? | ||
SONY |
SPP60
|
Test connector for alignment of rf section | How do you align rf section? | ||
SONY |
SPP50
|
Test connector for aligning rf section | How do you align rf section? | ||
SONY |
SPP90
|
After grabbing the line, unit shuts down after a few seconds | When talk button on handset is pressed, base unit and handsetgo on-line normally. after about 30 seconds, base unit drops theline and handset goes back to standby mode. if talk button is pressedagain, same situation occurs. | ||
SONY |
SPP80
|
After grabbing the line, unit shuts down after a few seconds | When talk button on handset is pressed, base unit and handsetgo on-line normally. after about 30 secs., base unit drops the line andhandset goes back to standby mode. if talk button is pressed again, samesituation occurs. also applies to s/n 226939, 2 | ||
SONY |
TCDD10
|
Distorted audio during playback | Plays normal for 30 seconds or so then bursts of static noise,then goes to all garbled static noise, then finally to no sound. some-times after this, it will stop playing and unthread. rec loop-through isfine. i have replaced ic-301, ic-311 and ic-529 | ||
SONY |
XR5000
|
No audio on tape left channel | No audio on tape left channel (forward and reverse). radiochannels ok. | ||
SONY |
CDXR77
|
Flashing segments in display | Display would flash segments erratically - especially whenunit is first powered up. after powered up, display would flashintermittently with wrong segments every second or so. | ||
SONY |
TAN77ES
|
No power | Unit has no power. | ||
SONY |
CDXR88
|
Will not accept specific disc | The eric clapton cd with the number 126074-2 re1 srct03will not play in cdx-r88. it will not load down. it gets stuck insidebecause the coating on the outside of the disc is not wide enough. itlets the led's light pass through so it does not think it | ||
SONY |
KV27TS20
|
Shutdown, replace yoke and r-578 | Set in shutdown. r-578 dissipated, reading zero on the 27,12, and 9.3 volt lines. | ||
SONY |
KV2680R
|
Shutdown, c-540 open | Set would shutdown intermittently due to high b+ (145-150vdc).replaced str3035 in regulator circuitry to no avail. r-608 (20 watt220Ω) was cool. set also showed no ripple at normal line voltage. | ||
SONY |
CPD1302
|
Shutdown | Set would shutdown immediately at turn on. pin 6 of ic-301measures approximately 12 volts. |