Sony Repair Tips
Search: sony
Results: 20073
Results: 20073
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
TAN77ES
|
Meter lamps continue to go bad | One row of lamps was out because there was a bad lamp. re-placed bad lamp and about 30 minutes later the other row went out becausea lamp went out in that row. replaced that lamp and then the other rowwent out. help - have three units with this proble | ||
SONY |
D15
|
The enter/remain or play function works intermittently | Enter/remain button or play button does not reach their res-pective switch when it is pushed. the enter/remain or play function doesnot work or intermittently. i have many units which have this problem. | ||
SONY |
VCT600
|
Loose top half on panhead assembly | Top half of panhead assembly was loose. | ||
SONY |
KV1395
|
Set would not turn on always - sometimes ok for 2-3 weeks | Set would turn on intermittently. found sv line wouldsometimes be 3.5 to 4.5v (would vary). | ||
SONY |
SL2710
|
Intermittent y signal in pause and betascan | Intermittently the luminance signal would disappear. the10.7mhz at pin 3 of ic-14 would come and go intermittently. | ||
SONY |
SL2710
|
Intermittent cracking noise in audio | Unit would produce a cracking noise in the linear audio, thishappened on record only. looking at rf envelope you could see a gap be-tween (a) and (b) head. first thought it was tape path but this did notmake sense since playback was ok. traced problem | ||
SONY |
KV27SXR10
|
No power, replace hdt | Set would not come on. traced hor. osc to base of drivetransistor, found no b+ on transistor collector. primary side of drivetrnasformer opened. | ||
SONY |
HVC2200
|
Part number for ib-1 and ib-3 on (cc-16) board | P60 of manual shows two component packs, ib-1 and ib-3. weneed the part numbers for them. if not available, please explain the un-usual symbols shown connected to pins 5 and 6 of ib-1. thanks. -hq comments: the symbols at pins 5 and 6 of ib-1 are as | ||
SONY |
D3
|
D3 with no audio | No audio, no data out of pin no. 78 of ic-601, muting at pin19 of ic-601 is high (4.7v) should be low (0v). 9v was on base of q-807should have been 0v. therefore, muting audio, q-807 shorted base, emitterjunction. | ||
SONY |
CDPC5F
|
Flashing display | Flashing display. | ||
SONY |
D170
|
Sled motor offset procedure | Sled motor offset procedure: reversal of steps 5 and 6 makeadjustment much easier. to do as instructed has pulsating voltage and isvery difficult. -hq comments: have not been able to confirm your problem. the procedurefor this player is the same as a | ||
SONY |
FH150R
|
Wrong part number | Part number for ic-601, page ta28 in fh150r service manual forthe amp ta-177r is incorrect. the number given is 8-759-941-52. thecorrect number is 8-749-941-52. -hq comments: you are correct. a service bulletin has been written. | ||
SONY |
CCDV3
|
Components on (ss-70) board do not match schematic | There is a descrete component diode between r-328 and c-321 onthe (ss-70) board. the board revision numbered is a-16. does the diodebelong there? -hq comments: tokyo said the -14 boards had descrete diode but the -16boards should not have one. | ||
SONY |
HVL80D
|
Part availability for front housing | Underwater camera light turns on in transporting of unit.heat generated from light melts front housing. front housing part is notavailable (see s/b 22). the need for this part exists. | ||
SONY |
SL2410
|
Capstan speed and phase do not lock | In bii the picture has noise bars and the audio is unstable.tp11 on the (ss-13) board should have a 50% duty cycle. the waveform isdistorted with a series of negative pulses. the waveform at tp9 is ok. | ||
SONY |
EVC8U
|
Servo speeds up when pause is released | The capstan servo speeds up when pause is released thensettles to normal play. | ||
SONY |
PCM501
|
Static is head on audio out | Static or distortion is heard on the audio out. | ||
SONY |
CFSW501
|
10khz noise in high speed dubbing | A 10khz noise is heard only in high speed dubbing. all otherrecord, playback functions ok. | ||
SONY |
CPD1303
|
Flagging at top of screen when used with mac ii | After about one hour of operation, a flagging would start at top of screen when used with mac ii. this problem would not be seen with multiscan generator at macintosh ii frequency. | ||
SONY |
CPD1302
|
Flagging at top of screen when used with mac ii | After about one hour of operation, a flagging would start at top of screen when used with mac ii. this problem would not be seen with multiscan generator at macintosh ii frequency. |