Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CPD1310
|
Unit is dead | Unit is not developing high voltage. low b+ (46v) of d6007(instead of 115v b+) low 17v (2v). decreased value capacitor c6007 330uf/25v. | ||
SONY |
KV27HFR
|
Picture blanks out after 1/2 hours | This set when first turned on, had a narrow picture aboutone inch each side. then a half hour later picture blanked out. checkedb+. i found 65v instead of 135v. sprayed super freeze on ic681, picturecame back but still narrow. | ||
SONY |
KV1926R
|
Picture shifted intermittently, replaced freq. synthesizer | When this unit first turned on, picture was fine. sometimean hour later, sometime a half day later picture was shifted. | ||
SONY |
KV2670R
|
Picture shrink virtically, ic-301 replaced | This tv had a raster shrink virtically (2 inches from topand 2 inches from bottom). vertical size control rv502 had very littleaffect. | ||
SONY |
KV2786R
|
Snow in picture, s/m error and wrong type ic-1112 installed | Snow in picture. ic1112 could not pass signal. it had beenreplace by a servicer with the wrong part. p/n in s/m is incorrect.it is for an invertor (ic1113) not a ff, which is what servicer installed. -hq comments: we will issue a s/b. | ||
SONY |
SL5000
|
P/n for metal plate | Need metal plate located beneath ref. no. 105, pg 4-3 of s/m. -hq comments: i removed this part from a defective unit and have sentit to your attention. | ||
SONY |
KPRM360
|
R5297 value is incorrect in sm, (4.7k 7 watt) see sb 307 | Set operates fine for approx. 20 min., then starts to showflagging at top of picture. investigation of e board revealed thatservicer had changed ic5001 (p/n 8-759-100-60), and r5297. servicerinstalled 4.7Ω 7w resistor as is listed in manual. this v | ||
SONY |
KV1981R
|
Wrong part number, d491 use 8-719-92-53 | Wrong part number. if install diode above it will short outafter overheating. | ||
SONY |
KPR4620
|
Screen p/n reversed in s/m, see sb 304 | S/m page 87 has the reference numbers for the lenses reversed.the diagram indicates that the fresnel lens is the outer lens and thelenticular lens is the inner lens. | ||
SONY |
CDXA10
|
System control would lock up | Unit's system control would lock-up with volume on high.no controls operative. | ||
SONY |
SLHF1000
|
Rotary transformer | Problem indicated a defective video head disc. this wasreplaced but did not solve the problem. additional tests pointed out adefective head drum ass'y. | ||
SONY |
KV20HFR
|
Shutdown, replace reg ic681 | After warm up 20 min. unit would shut down (power relay wouldopen contacts). shorted return side of relay coil to ground and measuredbase of q602 found 0.2vdc, traced problem b+ regulator, found pin 1 ofdm-36 reading 0.6vdc s/b 1.4vdc. | ||
SONY |
CDP510
|
Irregular disc rotation | Unit would not play discs. after pressing play, disc wouldspin with loud, irregular thumping noise. | ||
SONY |
D3
|
Poor tracking | Unit does not track very well. eye pattern looks very poor. | ||
SONY |
KV2080R
|
Hi pitch squealing, replace l1507 | L1507 causing an objectionable hi pitch squeal. | ||
SONY |
SLHFT7
|
Not recording audio | Not recording audio on longitudinal track. | ||
SONY |
KV1948R
|
Dead, replace d631 and r603 | R603 fails after one month of operation due to a missing d631on e-1 board from the factory. this is the second unit with this problem. | ||
SONY |
CDP110
|
Roller guide for chucking arm assy comes off | Roller guide for chucking arm assy comes off. this rolleris a brown one. | ||
SONY |
CDP510
|
Roller guide for chucking arm assy comes off | Roller guide for chucking arm assy comes off. this roller isbrown one. | ||
SONY |
WMF77
|
Incorrect part no for fwd idler assy | P/n for ref. 211 page 26 wm-f77 service manual is wrong.p/n x-3335-724-1 is no given, but this same number is also used asref. 233 same page called chassis assy, mechanism. need correct p/n forref. 211 idler assy. |