Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CCDV1
|
No time or date recording on tape | Unit would not record date or time information on tape. unitwould display date and time on ccd display and data indicator in view-finder would function normally. | ||
SONY |
CFSDW60
|
Wrong head | Please note enclosed samples, we need the correct rec/pb headfor deck a. the stocked part is incorrect. please advise. -hq comments: correct p/n is 1-543-406-11. we will issue a s/b. | ||
SONY |
SL2410
|
No capstan servo | The capstan servo on these units would not lock up. thecustomer tracking control pot was found to be open. the servo freq. wasclose but not locked. | ||
SONY |
KV1981R
|
Shut down, replaced open q502 and shorted c553 | No picture, then unit shuts off. | ||
SONY |
CDXA10
|
Car stereo service bulletin #73 (cdxa10 disc pack) | Disc pack can be safely and easily removed in 5 secs followingmy procedure rather than following s/b #73 (car stereo). use a flatobject (i use a straightened stainless steel clasp senior - made in japan.this clasp can be obtained at any stationery store | ||
SONY |
SLHF900
|
Popping noise in hi-fi sound | Audio popping. s/b #210 improved problem, but did noteliminate it. -hq comments: have servicer confirm that resistor and cap wereincreased to max specified value. | ||
SONY |
XR510R
|
No playback, no ams | No b+ to ic301. q329 was cold soldered (factory) on all legs. | ||
SONY |
CCDV5
|
Clogged heads | Distorted picture. | ||
SONY |
STRAV780
|
No stereo reception, searches but does not find stations | 1) manual tuning worked ok except for no stereo indicator.2) when performing search, indicator moved on spectrum display screen, butno station markers were placed on it. | ||
SONY |
KV2075R
|
Weak sound, replace q1404 | Audio is weak on full volume. | ||
SONY |
SLHF1000
|
Tape path | Customer had bought 2 identical machines. could not playtape recorded on machine #1 or machine #2 and vice versa. picture wouldbreak-up. | ||
SONY |
DT3
|
The turntable does not spin | 8.6v appear at the collector of q401 when only 4.5v should bepresent. q401 is found to be shorted. many dt-3 or d3 units have thesame problem. | ||
SONY |
SL2000
|
Substitute pinch roller | When this new substitute part pinch roller x-3669-307-6 isinstalled, the adjustment of the pinch closing limitter (step 3-11 page3-11) cannot be made to fall within the spec. this will cause a veryintermittent jamming of the pinch roller. | ||
SONY |
SLHF900
|
P/n for circuit board holder is missing | Part number for circuit board holder is missing from manual(see attached). a similar part used in the sl-hf1000 is listed in thes/m. -hq comments: the board holder is unavailable. however, we havereceived a few sample from tokyo. | ||
SONY |
BMC550
|
Part number omission | Part number for drum base assy is missing from service manual.found that the same part is used in bmc-1000. the part number for thedrum base assy is x-3690-109-1. | ||
SONY |
KV1975R
|
Intermittent no picture and no sound, c133 shorted | This unit had an intermittent no picture, no sound, no rasterand no function control problem. c133 was found to be shorting inter-mittently. | ||
SONY |
BMC110
|
Part number for arm plate | P/n for lever ass'y is needed. on page 100 of the s/m, thelever arm does not have a part number. the piece or shield is locateddirectly behind item 270. the bmc-550 and 660 do show a part number. -hq comments: as per s/b #264, part number is 3-681-64 | ||
SONY |
CDPC10
|
Defective optical block | Won't play. | ||
SONY |
CDP310
|
Disc will not play | Disc will not play and will scrape on inside of unit. foundroller guide on chucking arm had fallen off. this was a replacement unitwas like this new out of box. -hq comments: too early for a complete stock check. we will contactother regions for addi | ||
SONY |
CDP510
|
Spindle assy slips down | Caused disc's to be damaged. found spindle assy had slippeddown motor shaft. this was a new unit that failed out of the box. -hq comments: confirm to monitor this and similar models. we willhave stock checked when we can confirm enough additional cas |