Make Model Symptom Problem Solution By
SONY CCDV1
No time or date recording on tape Unit would not record date or time information on tape. unitwould display date and time on ccd display and data indicator in view-finder would function normally.
SONY CFSDW60
Wrong head Please note enclosed samples, we need the correct rec/pb headfor deck a. the stocked part is incorrect. please advise. -hq comments: correct p/n is 1-543-406-11. we will issue a s/b.
SONY SL2410
No capstan servo The capstan servo on these units would not lock up. thecustomer tracking control pot was found to be open. the servo freq. wasclose but not locked.
SONY KV1981R
Shut down, replaced open q502 and shorted c553 No picture, then unit shuts off.
SONY CDXA10
Car stereo service bulletin #73 (cdxa10 disc pack) Disc pack can be safely and easily removed in 5 secs followingmy procedure rather than following s/b #73 (car stereo). use a flatobject (i use a straightened stainless steel clasp senior - made in japan.this clasp can be obtained at any stationery store
SONY SLHF900
Popping noise in hi-fi sound Audio popping. s/b #210 improved problem, but did noteliminate it. -hq comments: have servicer confirm that resistor and cap wereincreased to max specified value.
SONY XR510R
No playback, no ams No b+ to ic301. q329 was cold soldered (factory) on all legs.
SONY CCDV5
Clogged heads Distorted picture.
SONY STRAV780
No stereo reception, searches but does not find stations 1) manual tuning worked ok except for no stereo indicator.2) when performing search, indicator moved on spectrum display screen, butno station markers were placed on it.
SONY KV2075R
Weak sound, replace q1404 Audio is weak on full volume.
SONY SLHF1000
Tape path Customer had bought 2 identical machines. could not playtape recorded on machine #1 or machine #2 and vice versa. picture wouldbreak-up.
SONY DT3
The turntable does not spin 8.6v appear at the collector of q401 when only 4.5v should bepresent. q401 is found to be shorted. many dt-3 or d3 units have thesame problem.
SONY SL2000
Substitute pinch roller When this new substitute part pinch roller x-3669-307-6 isinstalled, the adjustment of the pinch closing limitter (step 3-11 page3-11) cannot be made to fall within the spec. this will cause a veryintermittent jamming of the pinch roller.
SONY SLHF900
P/n for circuit board holder is missing Part number for circuit board holder is missing from manual(see attached). a similar part used in the sl-hf1000 is listed in thes/m. -hq comments: the board holder is unavailable. however, we havereceived a few sample from tokyo.
SONY BMC550
Part number omission Part number for drum base assy is missing from service manual.found that the same part is used in bmc-1000. the part number for thedrum base assy is x-3690-109-1.
SONY KV1975R
Intermittent no picture and no sound, c133 shorted This unit had an intermittent no picture, no sound, no rasterand no function control problem. c133 was found to be shorting inter-mittently.
SONY BMC110
Part number for arm plate P/n for lever ass'y is needed. on page 100 of the s/m, thelever arm does not have a part number. the piece or shield is locateddirectly behind item 270. the bmc-550 and 660 do show a part number. -hq comments: as per s/b #264, part number is 3-681-64
SONY CDPC10
Defective optical block Won't play.
SONY CDP310
Disc will not play Disc will not play and will scrape on inside of unit. foundroller guide on chucking arm had fallen off. this was a replacement unitwas like this new out of box. -hq comments: too early for a complete stock check. we will contactother regions for addi
SONY CDP510
Spindle assy slips down Caused disc's to be damaged. found spindle assy had slippeddown motor shaft. this was a new unit that failed out of the box. -hq comments: confirm to monitor this and similar models. we willhave stock checked when we can confirm enough additional cas