Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
RME100V
|
Editing with jvc hr-d225u vhs recorder | Editing using ccd-v8afu and jvc hr-d225u, jvc model will notwork with rme-100v. rec pause/rec is only actuated with isolated contactclosure to pause jack. -hq comments: rme-100v only outputs an active low level (0vdc).we will update our list of vhs com | ||
SONY |
CCDV110
|
No functions | Unit would not initialize, no functions. no led display.checked ic302 clock, worked fine. checked data lines, no outputs andall dc voltages were off. | ||
SONY |
KV2781R
|
Popping sound in audio, replace ic-101 on "a" board | Popping sound in audio when changing channels. also, whenmute button pressed, audio level would go high and stay high until volumelow function was pressed or set was turned off. | ||
SONY |
WMD3
|
Missing part number - rotor assembly | Incorrect: ref #141 p/n missing. description missing. correct: ref #141 p/n x-3310-905-00 description - rotor ass'y -hq comments: we issued a s/b in oct. 1986 concerning the missing p/nfor the rotor ass'y. it is tape recorder s/b #216. | ||
SONY |
PSLX255
|
No power | Repetitive failure of r806 in ta-ax430 unit caused byps-lx255. | ||
SONY |
CCDV3
|
Autofocus motor noise | Auto focus motor noise. | ||
SONY |
CCDV110
|
No picture in camera mode | No picture in camera mode. | ||
SONY |
CCDV3
|
Intermittent no color in camera mode | Intermittent no color in camera mode. replaced x721 on thevc-20 board that changed frequency from 28.636 mhz to 28.682 mhz.defective sample attached. -hq comments: a service bulletin will be issued shortly regardinga circuit change. | ||
SONY |
CCDV110
|
Unit dead | Open fuse f381 on the sc-6 board. tape inside unit. -hq comments: please try to determine the mode of operation duringfailure and check for bent pins on the multipin connector if you receiveany similar units. | ||
SONY |
CDP310
|
Disc will not clamp after loading | Plastic piece broken off left post that holds chucking armin place. | ||
SONY |
SLHF1000
|
Audio muting in pcm during recording/playback | Audio mute in pcm mode during recording/playback. | ||
SONY |
CCDV3
|
No camera video - playback ok | No video from camera, playback ok. camera video looks as ifhoriz. sync. freq. is off, but flashes bright sometimes. found x721on vc-20 board not oscillating. | ||
SONY |
CCDV110
|
No playback video | No video on playback. appeared to have defective video heads.rf output from heads, and head amp normal. found loss of gain in q227 onvi-21 board. | ||
SONY |
KPR36XBR
|
No left channel, resoldered ic5008/pin 7 | One speaker dead. | ||
SONY |
WMF77
|
Audio cuts out with movement | Audio cuts out with movement. | ||
SONY |
WMF77
|
No audio in right channel | No audio - right channel. | ||
SONY |
CFSW440
|
Inoperable play button | Play button not working. | ||
SONY |
CFSW360
|
Eats tapes | Eats tapes. | ||
SONY |
KV2792R
|
No sound, resolder t-801 | No sound. pix ok. | ||
SONY |
CCDV110
|
Camera would flash bright/dark | Video from camera had what appeared to be incorrect horiz.freq. and would flash bright/dark. playback from vcr section ok.found x701 on the cp-18 board had no cw output. the output pulsed, butwould not ring. |