THOMSON W7023U
Trips with brief line coll after loptx replaced Fop chip & zl11 cp o/c - looks like a brown cap
THOMSON TX92F
Led flashing at sw on (prot mode) Disable pin 4 of ip 70 ic tda8139 to over-ride prot cct - shows field coll; ic stv2145 (if02) was faulty, but still no functs - replaced eeprom - now bad col with green flashes - jungle chip faulty
THOMSON TX92 28DT73H
Reverts to st/by aft few mins Dry joints pins 1 & 2 loptx
THOMSON TX91
No sound aft dropped Ra08 22k sm res dislodged;
THOMSON TX90 CHASSIS
Int. white raster with flyback lines visible, or switches off. seems as if tsound is a cold solder joint. Replace tda8218 chip. it has occured many times with these st made chips.
THOMSON TX807CS 25DG17U
Sound missing except from scart Multi-sound processor is100 (msp3415d-po)
THOMSON TX807C 14MK15U1
No comp video via scart - ok off air pic Break between rv023 & rv022 (invisible)
THOMSON TX807C 14MG15U
Dull pic/low contrast - does vary slightly when adj Rl002 100k ¼w o/c in beam lim (in lop stage)
THOMSON TX807C 10MK16UF
Loud buzz on av i/p Iv001 tda9554ps/n1 u/s. fit micro kit part no.35190040
THOMSON TX807 25DG21U
Dead - st/by only Dry joint cl21 0µ14 1.6kv, loptr buh516 leaky - use buh517th or equiv
THOMSON TX807 20MG10C
Sound conversion to 6mhz Replace 2 filters q132 video & q134 sound for 6 mhz ones
THOMSON TX807
Service mode access |switch set on, put into stby. wait for stby led to go out. whilst holding down text button on r/c switch set back on continue to hold test button till menu appears. press text button again to access the different settings.
THOMSON TX805
St/by only Rp92 o/c (0.68Ω in 14" ) ( 0.56Ω in 20" )
THOMSON TX80
Dead with mains fuse o/c Tp 10 (s2000a or bu508a), cp08 (100uf/63v)
THOMSON RP46
Tripping - eht splitter faulty, new one has short life R18 220k hi res & check r9 100k 2w
THOMSON IKC2
No col via scart - ok off air 4.43mhz xtal
THOMSON IKC1
Int start up unless vots i/p is 160vac Cl65 smoother on the 13v rail (measured ok)
THOMSON ICC9 37MG73J
Pic break up with folded horizontal lines at bottom half Rf11 safety res 1r5 o/c pt no 15022560
THOMSON ICC9 37M973J
Service mode entering Switch on holding in blue txt button then press blue button again
THOMSON ICC9 37M973J
E-w bowing Iv01 stv2160 replaced & uprate cv46 from 10nf to 22nf sm; rl45 3r3 o/c, ll08 pt no 10092690, cl42 4µ7 160v