Search: toshiba
Results: 5617
Make Model Symptom Problem Solution By
TOSHIBA 3787DB
Tripping lightly from psu - all o/ps appear ok C819 22µ 100v low cap
TOSHIBA 3787DB
Tripping lightly Q802 coll low (should be 35v) - c819 22µ 100v
TOSHIBA 3787DB
Tripping - no leds All volts high - c833 4µ7 or 10µ
TOSHIBA 3787DB
Tripping - no led illumination If ht is high c833 4µ7 o/c
TOSHIBA 3787DB
No sound, ticking in speakers Ic601 la4282 (23318413)
TOSHIBA 3787DB
No dolby prologic surround sound Dj qd01 on the dolby pcb
TOSHIBA 3787DB
E-w error Q460 2sa178 (23314850) s/c
TOSHIBA 3738DB
Sound absent except for motorboating from rear spkrs Check audio o/p chips q601 & 2 la4282 (the supply will pulse if faulty) - check at pins 23 & 24 bb12 blue plug. unsolder pin 10 of chips to isolate faulty one. also could be due to u101a dolby dig module pt no 23781658. check customers speaker wiring.
TOSHIBA 349P9B
No sigs, field fold up & lines R327 6r2 o/c
TOSHIBA 349P9B
Field - stretched at top - concave at bottom C303 1µ 63v - to pin 31 ic501 ta8659n
TOSHIBA 349P9B
E-w faulty & field stretched at top C303 1uf 50v had leaked (located near jungle ic ta8659n)
TOSHIBA 3387DB
Service mode access Press "mute" on r/c , then press & hold "mute" on r/c again whilst pressing "menu" button on tv.
TOSHIBA 3387DB
Pic lim in bright areas on all i/ps Cz16 1µ 50v leaky - a/d i/p pin 3 ic qz01 comb filter
TOSHIBA 3387DB
Bright areas limited on pic Cz16 1µ 50v on a-d i/p pin 3 qz01 leaky
TOSHIBA 3377DB C7SS
Hiss from left/right chan at vol level 1 Replace multiplex/audio module h002 type mvgs48 pt no 23148275
TOSHIBA 3377DB
Patterning on pic and no sound (both off air and scart) Dj c897 (+8v line)
TOSHIBA 3377DB
Lack of width with e-w error D461 erc20-06 (23316582) leaky
TOSHIBA 3377DB
Blank raster, no osd or text Clock/data lines pulled down by faulty tuner (2332196)
TOSHIBA 3357DB
Dead due to surr spkrs dis'd Fuse link z889 5a o/c; q640 ta8211ah surr sound chip; q870 ta8256 front spkr chip
TOSHIBA 3339DB
Noise from centre speaker when switching to stanby Not faulty switch off prologic