Search: toshiba
Results: 5591
Make Model Symptom Problem Solution By
TOSHIBA TV2122
U19
Does not turn on, LED blinks C 865 changed - replace for a new one ADAMOR
TOSHIBA 2999
Image a little dark Ceramic capacitor on tube plate 102 This email address is being protected from spambots. You need JavaScript enabled to view it.
SEMP TOSHIBA VARIOS
TODOS OS QUE USAM O BU808
Transistor burnout It heats up a lot and burns Firstly we must measure the +b on the cathode of the diode (d-448) it must be more than 12 volts, if it is below that replace the diode, if the +b still remains low place a 10r resistor in parallel with the one already exists in the anode of the diode Ademar / Videira s.c
TOSHIBA TV2934(B) SL
SK9
Stretched image Capacitor c-301 Replace it TIAGO.ELETRO
TOSHIBA 2097
U16
Horizontal outlet getting very hot C416 x112 fake and q406 changed They will send me 10 x 112 that doesn't work. I bought the original TV and it's perfect. luiztvsom
TOSHIBA 7945MU
Device with a hoarse and low sound. Resistor smd hr441 Moroni Eletronica
SEMP TOSHIBA TV2922
Does not turn on, std-by lit, power supply normal Check q402 and c416 Diorge Coutinho
SEMP TOSHIBA TV2157MFS
U10
Normal league, blue screen Video card diode d921 (1n4148) delegado123
SEMP TOSHIBA TVC205
Vertical curled at the top Raa0 Pablo
SEMP TOSHIBA TS209CR
Vertical shakes and closes after hours of normal operation C304 Pablo
SEMP TOSHIBA TS209CR
Lack of vertical linearity C303 Pablo
SEMP TOSHIBA TS207VS
Jagged image C408 Pablo
SEMP TOSHIBA TS145VS
No image at top and bottom 15 Pablo
SEMP TOSHIBA TVC161 TVC164 TVC201 TVC204
Q803 Pablo
SEMP TOSHIBA TS147 TS167 TS207VS/CR
+b com +9v R812 open Pablo
SEMP TOSHIBA TS147 TS167 TS207VS/CR
No high voltage Q811 Pablo
SEMP TOSHIBA TS201A
Lacks vertical linearity C310 e c316 Pablo
SEMP TOSHIBA TS201A
White screen with no image and no sound C116 with leak Pablo
SEMP TOSHIBA TC1470
Green screen with white traces across the image Replace ic501 Pablo
SEMP TOSHIBA 2083 FAV
U11