Search: cce
Results: 4824
Make Model Symptom Problem Solution By
CCE HPS 1465
Doesn't work, burns fr400 of 1r. 10k c554 shorted.
CCE HPS 1481
It doesn't work and it's chirping at the power supply 10kpf c846 shorted.
CCE HPS 2080B
Works with noise in the power supply transformer 47x63v open c428
CCE HPS 2092
Doesn't work Fr914 of 22r open on trc board.
CCE HPS 1485
Vertical closed R305 from 330r open.
CCE HPS 2001C
It turns on and off and doesn't work anymore. Q802 semi-open
CCE HPS 1491
Doesn't work C807 exhausted 10x100v
CCE HPS 1402
High power supply Ic803 altered photo-coupler.
CCE HPS 1450R
No image, screen washed C426 aberto de 100k x 400v.
CCE HPS 2981C
No image, no sound and vertical closed. Ic801 reg de 9v.
CCE HPS 2070P
Contrast does not work. 220k r210 open.
CCE HPS 14R
Horizontal doesn't work. C404 shorted.
CCE HPS 2004
Doesn't work. C825 exhausted 47x160v.
CCE HPS 14R
Vertical folding at the top. R306 of 3k3 changed.
CCE HPS 2070V
Doesn't work Q400 short collector emitter.
CCE HPS 1470
Does not tune channels and AV does not work. Ic703 and q793.
CCE HPS 1425
Doesn't work. C417 in short 3k3 ceramic.
CCE HPS 1470DD
No image and does not turn off. R313 of 1r open.
CCE HPS 1491
Starts and activates protection Q806 com leak. x-ray prot.
CCE HPS1402
Aliasing the image and going out of horizontal frequency. 15k smd open r403.