HITACHI C2558TN
St/by - wont come out of using front controls Use hset - reason u/k
HITACHI C2558TN
Slow start up 12v rail low - c933 2200µ 25v
HITACHI C2558TN
High ht R941 100k, zd941 10v zener - ht = 157v
HITACHI C2558
Repeated failure of tda3654 field o/p chip Dry joint scan coil tag also replace flyback boost cap to pin 6 (47 or 100µ)
HITACHI C2557N
Weak sound & low contrast C758 100nf s/c alb line.
HITACHI C2556TN
Trips 3 - 5 secs aft sw on R950 68k hi res
HITACHI C2556TN
Int off when disturbed Check ht pot vr950 by replacement- & check r950
HITACHI C2556TN
Int loss of sound/pic Dry joints l7805 ic951 5v reg
HITACHI C2556TN
Int goes to st/by or off Happens when disturbed mainly - check wire links at front of pcb for dry joints
HITACHI C2556TN
Int goes dead only to reapear several secs later Dry joints pot r950 - tight up against plastic cradle
HITACHI C2556TN
Int dead Check dry joints ic951
HITACHI C2556TN
Int dead Dry joints set ht pot
HITACHI C2556TN
Dead R950 68k ½w hi res (near ht pot)
HITACHI C2556/2586
Ht setting 152v
HITACHI C2548TN
Jumping pic Fop chip responsible
HITACHI C2546TN
Tripping Check r950 68k, r951 12k, r952 82k 1/2w & check for dry joints
HITACHI C2546TN
Stuck in st/by prot cct in operation 12v supply low - zd952 11v zener leaky
HITACHI C2546TN
St/by only Drys on all regulators check frame ic replace 68k feed to ht pot and check the 12k next to it replace ht pot set ht to 152 volts and dry on r791
HITACHI C2546TN
St/by led lit - ht to lop stage but no line drive Dry joints q950 reg (under plastic support)
HITACHI C2546TN
Reverts to st/by aft a sec with "growling" Scan coils duff