Search: hitachi
Results: 1065
Make Model Symptom Problem Solution By
HITACHI C2166TN
Int trips Remove glue from ic950 & surroundings
HITACHI C2166TN
Int trip Ic952 5v reg faulty
HITACHI C2166TN
Dead with dim st/by light Dry joints ic902
HITACHI C2164TN C2564TN
Wont start , just momentarily energises then dies Check 25v supply to audio
HITACHI C2164TN
Trips at sw on Tda7263m audio o/p chip s/c
HITACHI C2164TN
To check psu - remove q904 & sw on If no volts replace r901 82k, r909 6k8
HITACHI C2164TN
Shuts off int Zd701 pt no 2339251m
HITACHI C2164TN
Int trip Zd701 pt no 2339251m
HITACHI C2164TN
Int start up - ok once going Dry joints q954 emitter in st/by sw cct
HITACHI C2164TN
Dead - psu shut down R901 82k 1/2w in psu
HITACHI C2164TN
Dead Check for dry joints r719 in trip cct
HITACHI C2156TN
Dead - trips once or twice at sw on High ht - r950 68k hi res
HITACHI C2156/2186
Ht setting 110v
HITACHI C2156 - C32WD2 &TC
Int goes to st/by Vr951 +b ht preset 1k goes int or microphonic
HITACHI C2146TN SERIES
Dead or int dead Dry joints r956 1k (under bob of glue)
HITACHI C2146TN ETC
Trips soon aft sw on Dry joints r719/716 (lh rear of loptx)- hard to access, also check r905 0r5 or 2x 1r in parallel
HITACHI C2146TN ETC
No sound Tda7263 audio o/p chip
HITACHI C2146TN
Shuts down onto standby Check ic950,ic951 and ic952 for dry joints
HITACHI C2146TN
Mode set up menu Switch on holding in "vol+" & "vol-" together; model no now displayed on screen; press 2 x rec buttons on hset together to display vers & standard; version 46 v1.0 (later ic v2.0c)....standard....i (for uk)..adjust with key 9....l.......key 8...dk.....key 0 bg.. 7...default...0 1 to 6 alters value tv button return to 0...a18 programme up button adjusts value.....loo programme down value adjusts value .....if h shown set is hotel mode....and is removed by -/-- button....after adjustment put set into standby...
HITACHI C2146TN
Int st/by Ic950 dry joints