HITACHI |
C2114T
|
No r/c functs aft ½ hr | Micro supply high at 5.35v - zener zd001 | ||
HITACHI |
C2114T
|
Loss of sigs/functs | Ic001 tmp47c1237n/n155 faulty - fit kit a523217 (new ic & links) | ||
HITACHI |
C2114T
|
Int loss of pri col | Rgb o/p trs breaking down | ||
HITACHI |
C2114T
|
Dead with s/c field chip 112v ht hi at 130v | R951 39k hi value and field chip | ||
HITACHI |
C2114T
|
Dead with 330v at chopper tr | R901 82k start up res o/c | ||
HITACHI |
C2114R
|
Still dead aft replacing psu comps blown (ht ok) | Ic601 ta8427k fop chip faulty | ||
HITACHI |
C2114R
|
Pic displaced to right | Clipper diodes d704 & 703 1n4531 | ||
HITACHI |
C2114R
|
Bright green raster with flyback lines | Crt faulty (s/c within tube) | ||
HITACHI |
C2114R
|
At switch on the raster would turn bright green wi | But this time the blue gun was affected. | ||
HITACHI |
C2086
|
Service mode | Press and hold down the tv/video key and then press power switch | ||
HITACHI |
C2086
|
Goes into prot mode | Syscon chip pin 36 leaky - replaced z90234 | ||
HITACHI |
C17P118 L
|
Standby - going into standby intermittently | Drys on transformer m600 , crack from pin 1 to d709. | ||
HITACHI |
C1719T
|
Dead | C906 4µ7 250v, zd903 p6ke130 & check r902/3 82k & c908 33µ | ||
HITACHI |
C1714TE -A15 CHASSIS
|
To access service menu | Press the following buttons on the remote: 4 4 status mute tv in that order and fairly quickly. the service menu is displayed. check that byte 1 = 7d; byte 2 = 20 these are two hex digits - to exit menu press st/by | ||
HITACHI |
C1714TE -A15 CHASSIS
|
No txt & delay in returning to st/by | Check 5v supply pin 44 micro - if low zd4001 5v1 zener is sus | ||
HITACHI |
C1714T ETC
|
Field o/p chip repeatedly fails | Replace ic 601. get two 33v zener diodes and connect them in series ( bzx79c33v) connect the anode to pin 1 of ic601 cathode to pin 2 of ic 601. fit 10nf 50v capacitor across the frame scan plug e701 on print side of the plug. if the ic still blows after this mod. a new crt is required. the tube is flashing over. this applies to all sizes of 14t/te range of sets | ||
HITACHI |
C1714T
|
St/by only | Dis supply to fop chip to check if this is cause - if then ok apart from field collapse, check fop chip ta8427k & d702 | ||
HITACHI |
C1714T
|
Pic size decreases with brightness | Ht low - cnx82a opto coupler ic901 s/c pri | ||
HITACHI |
C1646
|
Dead , fuse blown | Change q903 -t 633133 , q901 - 2390022 , ic901 t900406 zd903 t536171 zd904 - t 536171 , zd901 - t 536197 | ||
HITACHI |
C1646
|
Dead - tries to start. | R908 22k high or o/c . making ht rise so set shutting down instantly , chk ht with line o/c & bulb |