Sony Repair Tips
Search: sony
Results: 20073
Results: 20073
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
AE1
|
Purity poor | Scan coils shifted slightly - slacken & reposition | ||
SONY |
AE1
|
Powers up then trips off | Ic251 ( la4280 ) short | ||
SONY |
AE1
|
Picture dissapears and goes to snow | Check memory ic for -30v , if low check l807 10uh | ||
SONY |
AE1
|
Picture covered by fine shimmering horizontal blac | R544 330r o/c in field cct | ||
SONY |
AE1
|
Pic blanked out - sound ok | Check 18v supply - read 38v.; q608 2sd1761 | ||
SONY |
AE1
|
Only left hand side of pic visible with bowed side | Dry joints pins 17 & 18 plug/skt cnj51 av interface board | ||
SONY |
AE1
|
Off | Str50115, r2m, r621 1r 2w, & cp ps801 | ||
SONY |
AE1
|
No sound or pic | 12v at l606 low r822 ( 1k ) o/c | ||
SONY |
AE1
|
No r/c operation, no sound & pic - pic size varies with brightness | C615 1000µ 25v 14v res cap supply faulty | ||
SONY |
AE1
|
No picture - with sound. | D803 , r807 ( 1k ) | ||
SONY |
AE1
|
No picture - sound ok. | Mod. | ||
SONY |
AE1
|
No pic - sound ok | Faint pic present when a1 advanced - no rgb sigs at crt base - q801 beam lin tr not conducting - r812 68k o/c | ||
SONY |
AE1
|
No nicam | Bpf 1101 | ||
SONY |
AE1
|
No eht line scan drive approx 10v | D1504 sc on scart pcb | ||
SONY |
AE1
|
No eht - line scan drive at 10v | D1504 on scart pcb leaky | ||
SONY |
AE1
|
Motorboating sound in st/by | Dry joints on main metal plate across pcb | ||
SONY |
AE1
|
Motor boating noise in stby | D/j on heat sink audio output ic earth also check c612 | ||
SONY |
AE1
|
Luminance int | Delay line dl332 faulty - pt no 1-236-062 | ||
SONY |
AE1
|
Loses picture on channel change ( int! ) ic1003 pi | L8o7 int oc ( -30v feed ) | ||
SONY |
AE1
|
Looks like fine tune off will not lock nicam | Ic601 dry |