Search: sony
Results: 20100
Make Model Symptom Problem Solution By
SONY SDP777ES
No left or rear channel output in all modes - repl ic457 Traced problem back to ic457 pin 4 which had only noisesignal. ic457 pin 15 checked ok.
SONY MHCC33
Audio problem in cd mode - replaced ic107 Distorted audio in cd mode.
SONY LBTG1000
No open cd - cable ref. #4 shorted to gnd. Unit's cd door will not open. found cable #4 to be shortingto the chassis ground. the cable rubs on the bottom and wears theinsulations causing the short.
SONY HCDC50U
Hum in audio - tightened gnd screws Hum in audio.
SONY HCD541
Unit dead - replaced c843 Unit dead, + unreg. voltage is being supplied by saw542.reset voltage at pin #4 or ic714 located on main pcb is low. in this caseit was measured at 2 volts.
SONY HCD241
No power up - reset ic401 pin 17 to chassis gnd Unit would not turn on. five volt and 12 volt lines present.microprocessor has all must haves. jumped ry901 and unit functions withno display or audio.
SONY DTC57ES
Tape path alignment - removed spacer under capstan motor screw Cannot adj new type guide (unit always wrinkles tape.)
SONY CDPC345
Clicking and knocking when changing cd's - repl bracket assy As the cam gear turns and brings the bu bracket up a knock isheard. this knock causes the cd not to be chucked properly it will loadthe cd off center and jam up. the knock or clicking also causes the buholder to bounce into position.
SONY CDPC265
Will not read disc past 30 seconds - trace to m101 broken Disc player will only play for 30 seconds then unit won'tread disc anymore.
SONY CDPC245
Humming noise from machine - add weight(s) to bu assy As per sbhfp0381, stated to add weight and screw to optic toeliminate noise. works for some but not all. noise originated fromspindle motor assy x49175233. hot glued to 2 weights 496297901 toleft hand rear side of bu assy i cannot determine if this is
SONY BM146
R.f.i. causes record inhibit clt to activate, installshield R.f.i. was being picked up by the record inhibit head causingthe machine to drop out of record mode. the power supply of interference couldnot be removed.
SONY XRU500
No am or fm (replaced ic601, ic502, and d602) No 8v to tuner (ic601 bad and ic502 bad). ic601 had novoltage out of pin 5 (replaced ic601 then voltage out of pin 5). ic502had no voltage out of pin 52 & 37 (replaced ic502 then voltage out of pins52 &37 was ok). still no voltage to tuner, found d602
SONY XRC410
Gear strips, won't eject tape A gear on the reel assembly strips, the specific gear does not have a reference # other than 128 (bracket assy, reel). the striped gear prevents the mechanism from releasing the tape.
SONY XRC410
No power or display (r566 was open) Unit had no front panel display, no led's were on. tape wouldload, then eject. determined that acc check voltage at pin 46 of ic510was missing. following voltage back to d554, dual diode, it was stillmissing at the anode. located r566, had b+ on one
SONY XRC210
Gear strips, won't eject tape A gear on the reel assembly strips, the specific gear does not have a reference # other than 128 (bracket assy, reel). the striped gear prevents the mechanism from releasing the tape.
SONY XR430
No cd function (found d552 and ic551 defective) Unit connected to cd changer no functions at all when cdbutton is pressed. found d552 damaged, replaced with new diode, and stillno functions, then checked ic551. found no clock output from pin 4replaced with new ic (mm1175xf).
SONY XR340
No cd function (found d552 and ic551 defective) Unit connected to cd changer no functions at all when cdbutton is pressed. found d552 damaged, replaced with new diode, and stillno functions, then checked ic551. found no clock output from pin 4replaced with new ic (mm1175xf).
SONY MDX400
Distorted audio (static) when playing md's Unit had distorted audio when playing pre-recorded orrecordable md's.
SONY MDX400
Distorted audio in md mode, and counter freezes Unit had distorted audio when playing either type of md.distortion in left channel was different than right channel. track beingplayed could be heard through distortion, yet min/sec counter would jitterand not count at all.
SONY CDXU300
Dampers leak Since early '93, 6 leaking dampers have been found. all havebeen located at the right rear of the unit.