SONY |
SLV720HF
|
Unit records static on hi fi track | When recording on line in audio, steady tone, the audiosounded fine but when playuing back what was recorded, there was staticpresent. | ||
SONY |
SLV620HF
|
Stops after push play | No pulse at micro, stops after push play reads, l-01 abnormalt reel rotation) | ||
SONY |
SLV620HF
|
Line across middle of picture | When playback in ep mode picture is ok but will be distortedwhen it playsback in sp mode. -solution : replaced upper drum restored normal operation. | ||
SONY |
SLV585HF
|
Tape guide falls out | Retaining pin comes out of tape guide, cuaisng guide to fallout of unit. | ||
SONY |
SLV585HF
|
Li signal not being displayed | Signal input of li is not displaying -solution :ic102 is bad because it does not electronically switch.replaced this ic restored normal operation. | ||
SONY |
SLV20HF
|
Unit won't eject | When pressing eject, the tape guides would come to the homepostion but the basket wouldn't come up. | ||
SONY |
EVS700U
|
White linein picture on pb | Noise is generated in video on playback. | ||
SONY |
ACV500
|
The unit is not charging/r103 open | Unit dead. | ||
SONY |
EVS7000
|
Intermittenly does not load or eject | Intermittent loading or ejecting failure. found defective mode switch. solution: replace rotary switch. | ||
SONY |
KV9PT40
|
Parts in s/m power supply are not in the unit, no dc input | In the service manual schematic, for the power supply, itshows ic-651, q651, q652, and ry-602. these parts are not found in theset. -hq comments: the kv-9pt40 does not have the 12v dc input. thereforethe circuit components were not needed. this s/m | ||
SONY |
KV9DT40
|
Dead, replaced ic601 | Had voltage going to ic-601 but no osc. therefore no b+out. | ||
SONY |
KV32XBR50
|
High voltage remains, after turn off, replace relay | When unit is switched off, audio and video are muted, but hv remains. no clicking of relay observed and the ac side does not open and close. | ||
SONY |
KV32V15
|
Cable mouse doesn't work with panasonic converter | Cable mouse would not work with codes shown on owner manual. panasonic cable converter model tzpc1003. -solution :found correct code is 19. -hq comments: the panasonic box is using the scienific atlanta codes.my bet is scienific atlanta made the pan | ||
SONY |
KV32HSR10
|
"x" board part number, 8-752-035-54 | People order part number 1-629-624-11 ( x board) when theyreally need part number 8-752-035-54 (ic-251). this generates customercomplaints because 1-629-624-11 is a blank board. since this is not wantthe servicer needs the servicer has to reorder the c | ||
SONY |
KV32HSR10
|
No power, r660 open | Unit would not power up, 135 woult not come up even withf-61 lifted.-solution :found r660 open. | ||
SONY |
KV27XBR37
|
Buzz in left channel/ redressed the wires | Left channel has buzz when volume is set at second line on the display. | ||
SONY |
KV27TS29
|
Dead set, replaced q601, q602, r607, and r644 | Dead set found q601, q602, r607, r644 bad. then took anΩ reading across voc601. it read 400Ω. compared to another instock which read open. | ||
SONY |
KV27TS27
|
Picture int would roll or jitter, replaced c361 | Picture would intermittently roll or jitter and would losecolor purity. | ||
SONY |
KV27EXR20
|
No picture or sound, replaced d310 | No raster. set will power up and down. high voltage ispresent. video is muted. set has no vertical sweep, but a white line isobserved when increasing g2. ic302/pin 47 was only 1.6v. | ||
SONY |
KV20XBR
|
Immediate shutdown after turn on, replaced q503 | After replacing the fbt, the unit goes into immediate shutdown after turn on. |