Sony Repair Tips
Search: sony
Results: 20100
Results: 20100
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CFD30
|
Difficult removal/reinstallation of cd chassis | Cd chassis difficult to remove and reinstall. this can breakthe function switch & am/fm switch. | ||
SONY |
CFD21
|
Cd/no spin -install screw p/n 7-685-648-79 | When a cd is installed, it rubs against the chassis. | ||
SONY |
CFD12
|
Cd lid doesn't match holder, magnet: check supp #1 for p/n | The cd lids that come when you order ref 111 x33671331,holder cd assy will not work with the part above, holder magnets. | ||
SONY |
CFD10/12
|
Incorrect part number for optics: check correction #1 | The part number listed for the optic device is incorrect.the part number listed is 8-548-137-11 for model cfd12. this info is onpage 37, ref 405. for model cfd10 this info is on pg 64 ref 405.solution: the correct part number for the optic device is 8 | ||
SONY |
CFD10
|
No ac power: replace inlet jack p/n 1-540-009-11 | Switch inside inlet jack is defective. the switch gets stuck in the battery power position and will not accept the power cord. | ||
SONY |
SLVR50C
|
Smeary red on self recording / dl301 | Smeary red on self recording try to adj rv302 and rv303 onyc93 bdboard but still did not correct the problem. | ||
SONY |
SLV770HF
|
Does not autotrack | Autotracking does not work. found no rf envelope on pin60 of ic203.shield of r/p amp had sharp pin which shorted some traces on rv-33 board. | ||
SONY |
SLV720HF
|
Unit records static on hi fi track | When recording on line in audio, steady tone, the audiosounded fine but when playuing back what was recorded, there was staticpresent. | ||
SONY |
SLV620HF
|
Stops after push play | No pulse at micro, stops after push play reads, l-01 abnormalt reel rotation) | ||
SONY |
SLV620HF
|
Line across middle of picture | When playback in ep mode picture is ok but will be distortedwhen it playsback in sp mode. -solution : replaced upper drum restored normal operation. | ||
SONY |
SLV585HF
|
Tape guide falls out | Retaining pin comes out of tape guide, cuaisng guide to fallout of unit. | ||
SONY |
SLV585HF
|
Li signal not being displayed | Signal input of li is not displaying -solution :ic102 is bad because it does not electronically switch.replaced this ic restored normal operation. | ||
SONY |
SLV20HF
|
Unit won't eject | When pressing eject, the tape guides would come to the homepostion but the basket wouldn't come up. | ||
SONY |
EVS700U
|
White linein picture on pb | Noise is generated in video on playback. | ||
SONY |
ACV500
|
The unit is not charging/r103 open | Unit dead. | ||
SONY |
EVS7000
|
Intermittenly does not load or eject | Intermittent loading or ejecting failure. found defective mode switch. solution: replace rotary switch. | ||
SONY |
KV9PT40
|
Parts in s/m power supply are not in the unit, no dc input | In the service manual schematic, for the power supply, itshows ic-651, q651, q652, and ry-602. these parts are not found in theset. -hq comments: the kv-9pt40 does not have the 12v dc input. thereforethe circuit components were not needed. this s/m | ||
SONY |
KV9DT40
|
Dead, replaced ic601 | Had voltage going to ic-601 but no osc. therefore no b+out. | ||
SONY |
KV32XBR50
|
High voltage remains, after turn off, replace relay | When unit is switched off, audio and video are muted, but hv remains. no clicking of relay observed and the ac side does not open and close. | ||
SONY |
KV32V15
|
Cable mouse doesn't work with panasonic converter | Cable mouse would not work with codes shown on owner manual. panasonic cable converter model tzpc1003. -solution :found correct code is 19. -hq comments: the panasonic box is using the scienific atlanta codes.my bet is scienific atlanta made the pan |