Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
ITA200
|
No ogm greeting - resolder c317 | No ogm. c317 is not soldered on one side. | ||
SONY |
ITA200
|
No ogm activation - replace line jack mj101 | Intermittent ringing in unit. found telephone line jack mj101to have a defective ring connection. | ||
SONY |
ITA200
|
Distorted ogm greeting/static - resolder c333 | Static mixed with greeting playback. -solution : resoldered c333. -hq comments: c333 is across speaker to prevent static. | ||
SONY |
ITA200
|
No ring, no connect - replace fuse f101, p/n 1-532-866-11 | No ring, no connect. fuse open. | ||
SONY |
ITA200
|
Distorted ogm greeting - replace ic306, p/n 8-759-267-56 | Ogm distorted. ogm output distorted at ogm ic 306/pin 14. | ||
SONY |
ITA200
|
No mech motion/tape clip no part # of tape clip in manual | No mechanical motion. the mech needs a new tape clip. no part# in service manual | ||
SONY |
ITA200
|
No ring - replace q102 and q101 | Unit would not ring. found q102 shorted e-c, also q101 open | ||
SONY |
ITA200
|
No erase - replace r324, p/n 1-249-331-11 | Unit would not erase. r324 was out of spec, it was 118kinstead of 470. | ||
SONY |
ITA200
|
Distorted time greeting - replace ic302, p/n 8-759-912-77 | Distorted audio coming out ic302 pin 8. | ||
SONY |
ITA200
|
No ogm and plays fast - replace ic401, p/n 8-759-420-85 | No ogm and unit plays fast. unit lock up after set up and leddoesn't light. | ||
SONY |
ITA200
|
No mechanical motion (ff slow) - replace ic401 | Ff slow. | ||
SONY |
ITA200
|
Low ring - replace speaker sp301, p/n 1-504-541-11 | Low ring. found sp301 defective. | ||
SONY |
ITA200
|
Unit seizes a line when on hook - replace fl101 | Unit seizes a line when on hook. found fl101 shorted. -solutioon: replace fl101. -hq comments: fl101 is the input filter straight out of the telephoneline. when shorted it was loading down the tel line, simulating an offhook condition. | ||
SONY |
ITA200
|
Distorted audio in tape playback mode | Distorted audio on playback mode. take up supply reel bent. | ||
SONY |
ITA200
|
Mechanical noise - repair or replace mechanical deck | Clicking noise in playback. found slightly bent supply/takeup reel. -solutiion: repair or replace mechanical deck. | ||
SONY |
ITA200
|
Defective date/time, ogm, memo, conv, rec - replace board#11 | Unit had defective date/time, ogm, memo, conv and record.found key tad board (ref#11) to be cracked. -solution :replaced key tad board (ref#11) - c309 , t201 also damaged. | ||
SONY |
ITA200
|
Eats tapes - replace mechanical deck (ref 51) | Found spindle sticks and causes tape to skip/stop, eats tapes. | ||
SONY |
ITA200
|
No mechanical motion - adjust head hrpe301 | No mechanical motion. in play mode, tape is seated slant whenmech is in motion. | ||
SONY |
ITA200
|
Memo or playback cuts off after 3 sec - replace ref 53 | Memo or playback cuts off after 3 seconds. found ph301(sensor) defective - constant high on reel | ||
SONY |
ITA200
|
Intermittently dials wrong number - replace dialer ic101 | Unit would intermittently dial wrong phone number. foundthe #5 button would frequently dial at the #2. this would happen over 50%of the time. |