SONY |
TAAV601
|
Unit in protection mode | Unit goes into protection mode after 30 - 45 minutes. thetechnician replaced ic-700 and q-700, same problem. found 1v on pin 1 ofic-700, +24v on collector of q-700 and +26v on ic-600 pin 5 and 4. | ||
SONY |
STRAV710
|
Green tape monitor lamp flashes - unit will not turn on | When you apply power to unit, the tape 2 lamp flashes and themicroprocessors are locked up. nothing functions. | ||
SONY |
CCDTR6
|
No picture through camera | There was no picture through lens. found iris defective. | ||
SONY |
STRV6
|
Noisy switches | Popping sound when subsonic switch is moved. | ||
SONY |
ITD100
|
No dial tone | No dial tone. while holding handset to ear, hang up line andyou will hear what sounds like a capacitor slowly discharging, (bomb dropsound). sometime after the discharge noise, it will start grabbing anddropping the line. also pertains to serial numbe | ||
SONY |
TAM50
|
Low ogm playback to caller - icm cuts off | When the tam answers an incoming call, the ogm will be playedout the line at a low volume level and the icm will be cut off inter-mittently. this is caused by zd-1 leaking and allowing the line currentto drop below the minimum level required to hold the | ||
SONY |
ITD100
|
Multiple intermittent problems | Key pad defective/intermittent, no dial tone, no mute, no sidetone. cable has been cut by components on main board. also applies toserial number 10510. | ||
SONY |
DTC75ES
|
No display - unit functions normally | There is no display at all. however, all functions on theunit work normally. | ||
SONY |
DTC75ES
|
Door will not open to eject the tape | The door can't be opened to insert/eject the tape. the motorcan be heard running. | ||
SONY |
HST201
|
Tape (a) won't play | Tape (a) won't play. found bad motor. | ||
SONY |
CDXR79
|
Skips | Skips on all discs. found spindle motor did not have suffi-cent torque. | ||
SONY |
CDXR77
|
Skips over bumps - more sensitive the longer unit is on | Skips, adjusting did not completely solve the problem. foundspindle motor lacking torque. | ||
SONY |
STRAV980
|
Q-801 overheating | Q-801 would overheat because the emitter was getting pulleddown to 26vdc and the collector to 28vdc. traced back to filaments andtransformer as our loads. disconnected transformer at cnp-802, b+ return-ed to normal. reconnected transformer and disconn | ||
SONY |
CFD760
|
Service mode does not work | Cannot check sled motor or focus search when in service mode.i have checked two units and get the same response. -hq comments: the procedure shown in the service manual for entering theservice mode is incorrect. to enter the service mode, make sure pow | ||
SONY |
TCWR510
|
Missing part number | The spring does not show on the service manual. -hq comments: the spring in question is ref. number 56, part number3-391-096-01. the other springs are part of the md sub assembly and arenot listed separately. | ||
SONY |
SPP110
|
Part number of fuse not listed in service manual | I couldn't get serial number but some spp-110s have fuse(ref no f-101) between l-604 and vdr601. need supplement and part number. -hq comments: you were looking at the spp-110/150 service manual whichdoes not include the fuse. please look at the spp-1 | ||
SONY |
CCDF55
|
Ccdf55 shutdown problem | |||
SONY |
SPP150
|
10.24 mhz crystal replacement does not fit | When ordering and inserting a new 10.24 mhz crystal, the newcrystal does not fit in the handset. -hq comments: the reason for this is that there were originally 2 sizes:a short one for the handset and a tall one for the base. however, theyboth have the | ||
SONY |
SPP110
|
10.24 mhz crystal replacement does not fit | When ordering and inserting a new 10.24 mhz crystal, the newcrystal does not fit in the handset. -hq comments: the reason for this is that there were originally 2 sizes:a short one for the handset and a tall one for the base. however, theyboth have the | ||
SONY |
SLV676UC
|
No functions after unpluging and re-inserting ac plug | All functions are disabled after pulling the ac plug thenplugging it back in again. |