Search: sony
Results: 20072
Make Model Symptom Problem Solution By
SONY KV-X2963E - AE2
Starts and then stops, LED flashes 13 times Substituir d802 (rpg10) e r854 (0,47Ω)
SONY KV-25R2E
The "bu" burns and the LED flashes twice Change the "bu" and solder the t531, horizontal driver transformer
SONY KV29FC20E
Has sound. Sometimes it blocks the video. Shaking the chassis cannot reach a conclusion. Resolder ic301 cxa21140s, although nothing is noticeable
SONY KV-M21_ _ CHASSI BE2A
Starting color ok. after 3 to 4 min. blinks and disappears Tda8304
SONY CHASSI BE5E
Does not work, LED blinks 4x. eliminating protection (pin 1 from up to ground) and forcing on condition (base shunt with q603 emitter), it starts horizontal and vertical but without control. Cpu
SONY KV-28WX1E
Very high power supply, 180v instead of 120v, and the d611 immediately burns out R606 -- 68Ω, interrupted
SONY KV-M2100
Color failure Trimer ct332 30pf, replace with another model, the original one is fake
SONY CHASSIS AE1C
When turned on, it is on channel 59 and the volume is at maximum. When pressing the p+ key it goes to channel 00 but immediately returns to 59. Replace a eeprom (ic005).
SONY CHASSIS AE1C
East-west damage and/or excessive height. Ic tea2031a (on j board) and sometimes coil l806 on main board.
SONY CHASSIS BE-2A
Distorted image in the central area of ​​the screen, concavities on the sides, east/west does not react to adjustments The fault is located in the pin-out circuit (ic801 ba4558), it is difficult to explain the symptoms of this fault. pin 1 of ic801 had 10v, pin 3 had 0.6v, base of transistor q803 0.6v. Looking at the diagram you can see wsound the errors are, the cause is r809 of 3
SONY KV-M2100E CHASSIS BE-2A
"pin amp" and "h-size" do not work correctly, cannot be adjusted. See the following components: c807 1nf/ 2kv c806 47nf/250v, lastly ic 502 tda8304.
SONY BE4A
Image with saturated color (no luminance), unable to obtain black and white Replace memory
SONY KV21FX20E CHASSIS FE 1A
Image with pillow effect error 5 Cold solders on IC301 cxa2140s y/c jungle amplifier and r548 4.7Ω 1/4w open-----adjustment in service mode
SONY KV28FX60E CHASSIS AE 5
When turned on, a horizontal white line appears on the screen, little by little the image appears with traces across the entire screen 820k r5386 changed on the kinescope PCI
SONY KV-14TE1 CHASSIS BE-4
Does not turn on, the LED flashes 6 times According to the service manual, 6 flash corresponds to "overvoltage / overcurrent protection (pin 52) high", pin 52 of the processor has 5v when it should have 100mv, the protection circuit is armed. in this case it was due to a short circuit in the line transformer
SONY KV-DX21TD CH.AE1
Sometimes the vertical shrinks by 10 cm at the bottom and top During manufacturing, the solder caught one of the r1517 pins, leaving the island with the copper visible (board j1)
SONY KV-28FX65E
Green and red horizontal bars appear Ic tda-6111q (red cathode) on the kinescope board
SONY KV21R1E -BE5
Does not light up, blinks 10 times Transfer. hr7762 lines
SONY KV-E2943E
Tries to start but reverts to st/by, led b flashes 3 times Line transformer with internal leakage
SONY KV-E2943E
Does not start, led b flashes 13 times R681 open