Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
SLV555UC
|
Ics on the power block | Currently ic-201, ic-202, ic-203 and ic-204 of the powerblock are unavailable from kcp. also, part numbers have not beenassigned to them. -hq comments: the part numbers of the ics are asfollows:ic201 - 180879611ic202 - 180879511ic203 - 180802211ic204 - | ||
SONY |
SLV353UC
|
Ics on the power block | Currently ic-201, ic-202, ic-203 and ic-204 of the powerblock are unavailable from kcp. also, part numbers have not beenassigned to them. -hq comments: the part numbers of the ics are:ic201 - 180879611ic202 - 180879511ic203 - 180802211ic204 - 874992043 | ||
SONY |
SLV757UC
|
Head gap size | What is the head gap size of the slv-757? | ||
SONY |
SLV353UC
|
Head gap size | What is the head gap size of the slv-353? | ||
SONY |
CDXA30
|
Skipping in cold weather. | A dealer reported that he has two complaints of these unitsskipping when the temperature is under 25 degrees. units ok after carand unit operates for a while, or temperature warms up. have you heardof this? -hq comments: the cold weather skipping is d | ||
SONY |
CCDF35
|
Plastic mold on chassis broken. | A molded piece of plastic that goes into the cassette to holdit firmly was broken. the machine worked o.k., except for rewind tapewould get chewed on top. reason is, this plastic was broken, and thetape is not held firmly to the chassis. | ||
SONY |
MDP510
|
Crosstalks appears with ld, cd spins but shuts off | When i play ld disk, cross talks appears. when i play cddisk, it spins two or three times, but it shuts off. rf signal distorted. | ||
SONY |
CDPC50
|
Motor assembly spindle | The spindle motor is mounted in reverse polarity. | ||
SONY |
SPP50
|
No communication between base and handset | Handset works with b & k 1050 analyzer, but would notcommunicate with base. | ||
SONY |
SPPS10
|
Buzzing noise from base unit | I have seen this problem on several units - after the baseunit gets hot, you hear a loud buzzing sound. | ||
SONY |
KPR4110
|
Poor convergence, replaced r-6111, 6112, and 6114 | After changing defective stk ic on d pcb convergence, stillwould not function normally. | ||
SONY |
CCDTR5
|
No functions, caution light blinks | Unit powers up, but no functions. tries to eject, andcaution light blinks. | ||
SONY |
CCDSP7
|
Lines in playback | Herring bone in playback after a couple of minutes. problemis present if self-recorded or pre-recorded tape used. | ||
SONY |
D25
|
No operation from ac adaptor or bp100; o.k. on bp2 | Bad connection of collector of q-414. | ||
SONY |
D15
|
Power cuts out, intermittant battery charge | Intermittently the power will cut off. sometimes this willhappen when the unit is lightly touched. also noticed that the batterywill not completely charge at times. i have seen several of these units. | ||
SONY |
KV1928R
|
No tuner functions / fm station audio bleeding through,cp102 | Snow, no tuner function, fm audio bleeding through | ||
SONY |
CCDF40
|
No auto focus/zoom | No autofocus/zoom. | ||
SONY |
KV1380R
|
Crt | Crt in unit has the crt, coil (degauss) and metal shield asone complete unit. replacement crt comes just with the crt. we need thecomplete assembly part number. -hq comments: there are two types of crts being used - one is in theservice manual. the o | ||
SONY |
SLV555UC
|
Head gap size | What is the head gap size of the slv-555? | ||
SONY |
SPPS10
|
Static in handset | Static reception. found c-503 on rf input section of handsetrf pcb was touching other sections of (rf) board. |