Sony Repair Tips
Search: sony
Results: 20072
Results: 20072
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
XM1
|
Defective ic301 and ic102 | The oscillator and its associated amp were shorted on thisunit. naturally there was no pwm output and the sound was very low anddistorted. | ||
SONY |
TCFX66
|
Loose chassis ground screw | User complained remote control (rm50) would only work after1-2 hour warm up. | ||
SONY |
TAYX7F
|
Volume increases | Dealer has 2 units out of box that would intermittently goto max volume after warm-up. this is a motorized volume control, and thedrive transistors for the motor have open circuits at the bases when thev/c is not being driven. | ||
SONY |
STRVX5
|
Time constant of protection relay too long | The speaker relay delayed an excessive amount of time beforeopening its contacts at turn off. this created an occasional pop throughthe speaker. we determined that the time constant-associated withc718/r743 was too long. reducing c718 from 220 uf to 1 | ||
SONY |
PSX800
|
Tonearm would drop | When the tonearm was going down, before the stylus touched therecord, the muting relay clicked and the tonearm dropped. | ||
SONY |
PSX800
|
P/n error in s/b | Incorrect p/n listed page 54 of manual - p/n listed8-719-990-03 should be 8-719-910-03. | ||
SONY |
PSX600
|
Defective ic105 and r170 | Zero balance drifts. | ||
SONY |
PSLX500
|
Defective socket | The copper sleeves in the socket of the p-mount were pushedall the way back into the tone arm. i have received several reports onthis problem. | ||
SONY |
PSFL7
|
Pins out of place | The copper sleeves in the p-mount socket were pushed backtoo far to make contact with the pins of the cartridge. | ||
SONY |
ICFD11W
|
Missing ground jumper | When frequency display button was pushed, frequency changedand the station was lost. this was the same problem as reported 2/16/82dk-2-1. it appeared to be a ground loop problem. | ||
SONY |
ICFC55W
|
Leaky c115 | Segment on right channel was not showing proper number. allsegments lite up although a 1 should be shown. found c115 leaky. | ||
SONY |
ICFC20W
|
Defective q4 and q5 | Either q4 was leaky or q5 was open. am on while switch infm position. | ||
SONY |
ICF200W
|
Open r36 | When the unit is turned on after a couple of minutes a clicking noise is heard at the speaker. | ||
SONY |
CDP101
|
Out of alignment | High-frequency squeal through audio system with cdp-101 inany mode (stop/play/pause). checked completely and looked at output withoscilloscope. no high frequencies were audible. | ||
SONY |
CDP101
|
Loose right rail on sled | Loose right rail on sled. holder bracket missing. | ||
SONY |
CDP101
|
Defective cx-79034 | Static noise in both channels after 8 to 10 minutes. foundnoise being generated at output of cx-79034. | ||
SONY |
CDP101
|
Out of alignment | Rumble in audio. checked unit and found no problem. problemcould be in software or playback system. did complete alignment for unit,focus servo slightly out of range. returned to customer. | ||
SONY |
CDP101
|
Shorted wire | -10 volt line (from cn542 to cn536) was shorted to chassisnear bracket (bottom) to the rear of the sled assy. | ||
SONY |
XR77
|
Large distortion | Unit produced large distortion during tape operation withoutboard display no. 'dpl -el. | ||
SONY |
TCK81
|
High torque measured | After installing new take-up arm assembly, forward torquemeasures 55 to 65 q/cn. this may be contributing to tape skew problems,by requiring increased back tension. |