Search: sony
Results: 20072
Make Model Symptom Problem Solution By
SONY TCFX33
Problems around ic501 Unit will not lock into play mode and the service manualschematic does not agree with its own board layout in the book andneither agree with the board in the unit. -hq comments: release from play could be initiated by reset pulseor slow oscillator (r-c
SONY TCFX30
Grounding spring needed Intermittent static noise was recorded when humidity levelsare low, erase and r/p heads were eliminated by grounding to chassis thisproblem occurs both on record and playback. -hq comments: 1) please apply grounding spring to erase head as outlinedin ta
SONY TAN88
Open c410 The 78v line was reading about 110v on this unit and thesound was distorted. adjusting rt401 had little effect. we found c410to be open and causing the problem.
SONY TAF55
Shorted d406 The 15v line was down on this unit. we found d406 shorted(located in regulator circuit).
SONY STRVX6
Poor connections on q414 This unit had a dim display and erratic tuning q414 was found to be poorly soldered on the base and emitter leads.
SONY PSX75
Arm needed adjustment Cantilever of cartridge was being pulled to one side, bendingit eventually also mistracking in one channel, poor dynamic range, etc.
SONY ICF2001
Error in pcb diagram When rd amp fails, technician replaces q52 as labeled on pcb,diagram is incorrect.
SONY CFS10
End of tape sensor not aligned As tape moves in play mode - end of tape sensor is not alignedfully with width of tape causing uneven pressure and wrinkling of tape. -hq comments: the crease in the tape is indeed caused by excessivepressure as well as uneven placement of the pu lever
SONY AUDIO GEN
T/n #8467 T/n #8467 list ic cx807-f1 and cx807-f3 as applicable to wm-2.however wm-2 uses cx808 on first and second type board an cx887 on thirdtype board. is cx807-f1 and cx807-f3 replacement for cx808 or cx887? -hq comments: cx-807 and cx-808 ics are identical
SONY XR70
Tab adjustment needed It will not accept tape. cause: eject lever (#387) fails toengage the pin on (#385) when tape is inserted.
SONY XO5
Defective switch This unit had a bad hum in the phono mode (unless the switchwas pushed in and held in hard). the small switch (muting) along side s2would not make contact unless switch was held in.
SONY WMD6
Foil missing No ff and rewind. motor started about 2-3 seconds after theplay switch is pressed.
SONY TCM5
Missing parts in s/m The mechanical layout on page 15 of the s/m is missing parts.
SONY TCFX1010
Broken erase head wire This unit had a distorted output at the p/b head(non-symetrical sine wave). this of course prevented the auto calibrationcircuit from functioning. we found a broken wire at the erase head to bethe problem.
SONY TC530
Replacement motor is larger Ic624-si motor substituted by p/n 8-832-627-00, type ic624hi. servicer states motor sub is physically larger and mounting holesare different. -hq comments: motors are direct replacement.ic624-si motor (8-832-624-09/02) = ic624-hi motor (8-832-627-00)
SONY TC250
Replacement part different X-346-011-0 is too small in diameter. the other idler part #x-027-003-0 looks more like correct diameter. -hq comments: tc-250 unit is approx. 15 years old. similar model istc-350 and tc-102. p/n for its idler is x-002-701-92 and currentlyavailable.
SONY STRVX6
Defective ic503 This unit erratically displayed two or three led segments.we found the drive ic to be defective.
SONY STRVX6
Repeated inverter failure Unit had been serviced twice before for inverter transistorfailure. first time, it was modified by moving q801 regulator transistor.second time, unit was cooked 2 weeks. before being sent back to customer,where it failed again after 3 hours of operatio
SONY SPP11
Dialing pulse does not go through Intermittently when dialing out gets a busy signal and thenumber being called rings only once and then dead line. -hq comments: although no history of such a problem, there are twothings i can think of for an incomplete call. 1) the dialing pulse width
SONY RT66
Shorted d1314 When depressing the pause switch in play mode, the unit goesinto ams mode and stops operation (head goes down), if there is a signalplayed back.